OUTPUT SETTLING AND GLITCH
The AD660’s output buffer amplifier typically settles to within
0.0008% FS (1/2 LSB) of its final value in 8 s for a full-scale
step. Figures 7a and 7b show settling for a full-scale and an LSB
step, respectively, with a 2 k , 1000 pF load applied. The guar-
anteed maximum settling time at +25 C for a full-scale step is
13 s with this load. The typical settling time for a 1 LSB step is
2.5 s.
The digital-to-analog glitch impulse is specified as 15 nV-s typi-
cal. Figure 7c shows the typical glitch impulse characteristic at
the code 011 . . . 111 to 100 . . . 000 transition when loading
the second rank register from the first rank register.
REV. A
–200
–600
–400
+10
–10
400
200
–10
600
+10
0
a. –10 V to +10 V Full-Scale Step Settling
0
0
0
0
0
Figure 7. Output Characteristics
1
c. D-to-A Glitch Impulse
1
b. LSB Step Settling
2
2
10
µs
µs
µs
3
3
4
4
20
5
5
0
–200
–600
400
200
–400
600
–9–
DIGITAL CIRCUIT DETAILS
The AD660 has several “dual-use” pins which allow flexible op-
eration while maintaining the lowest possible pin count and con-
sequently the smallest package size. The user should, therefore,
pay careful attention to the following information when applying
the AD660.
Data can be loaded into the AD660 in serial or byte mode as
described below.
Serial Mode Operation is enabled by bringing SER (Pin 17)
low. This changes the function of DB0 (Pin 12) to that of the
serial input pin, SIN. It also changes the function of DB1 (Pin
11) to a control input that tells the AD660 whether the serial
data is going to be loaded MSB or LSB first.
In serial mode HBE and LBE are effectively disabled except for
LBE’s dual function which is to control whether the user wishes
to have the asynchronous clear function go to unipolar or bipo-
lar zero. (A low on LBE, when CLR is strobed, sends the DAC
output to unipolar zero, a high to bipolar zero.) The AD660
does not care about the status of HBE when in serial mode.
Data is clocked into the input register on the rising edge of CS
as shown in Figure 1b. The data is then resident in the first rank
latch and can be loaded into the DAC latch by taking LDAC
high. This will cause the DAC to change to the appropriate out-
put value.
It should be noted that the clear function clears the DAC latch
but does not clear the first rank latch. Therefore, the data that
was previously resident in the first rank latch can be reloaded
simply by bringing LDAC high after the event that necessitated
CLR to be strobed has ended. Alternatively, new data can be
loaded into the first rank latch if desired.
The serial out pin (SOUT) can be used to daisy chain several
DACs together in multi-DAC applications to minimize the
number of isolators being used to cross an intrinsic safety bar-
rier. The first rank latch simply acts like a 16-bit shift register,
and repeated strobing of CS will shift the data out through
SOUT and into the next DAC. Each DAC in the chain will
require its own LDAC signal unless all of the DACs are to be
updated simultaneously.
Byte Mode Operation is enabled simply by keeping SER high,
which configures DB0–DB7 as data inputs. In this mode HBE
and LBE are used to identify the data as either the high byte or
low byte of the 16-bit input word. (The user can load the data,
in any order, into the first rank latch.) As in the serial mode
case, the status of LBE, when CLR is strobed determines
whether the AD660 clears to unipolar or bipolar zero. There-
fore, when in byte mode, the user must take care to set LBE to
the desired status before strobing CLR. (In serial mode the user
can simply hardware LBE to the desired state.)
NOTE: CS is edge triggered. HBE, LBE and LDAC are level
triggered.
AD660