pt8a262w Pericom Technology Inc, pt8a262w Datasheet
pt8a262w
Available stocks
Related parts for pt8a262w
pt8a262w Summary of contents
Page 1
... CDS input to disable day time operation is desired. Applications • Energy saving auto-switch in Garden, kitchen, bathroom, corridor, storage or yard • Auto light in meeting room Ordering Information Part Number PT8A261P / PT8A262P PT8A261W / PT8A262W PT8A261DE / PT8A262DE Comparator latch circuit Voltage divider Control circuit Regulator ...
Page 2
Pad Location Pad Location of PT8A261DE Die No. Pad Name X Coordinate GND 570 TRIAC 570 OSCD 570 OSCS 570 ZC -378.8 CDS -30.1 MODE 570 V -197 136.9 CC Note: Substrate is connected to GND PT0075(04/03) ...
Page 3
Pad Location of PT8A262DE Die No. Pad Name X Coordinate GND RELAY OSCD OSCS ZC -378.8 CDS -30.1 MODE V -197 136.9 CC Note: Substrate is connected to GND PT0075(04/03) 1470um CDS ZC OSCS MODE V CC ...
Page 4
... Non-inverted input of first operational amplifier, connected directly to source of PIR sensor Inverted input of first operational amplifier Output of first operational amplifier Non-inverted input of second operational amplifier. Inverted input of second operational amplifier Output of second operational amplifier 4 PT8A261/262 PIR Sensor Light Switch Controller PT8A262P/PT8A262W GND 1 16 OP2O 2 15 OP2N 3 ...
Page 5
Functional Descriptions The PT8A261 and PT8A262 are CMOS LSI chips designed for automatic PIR lamp control. They can operate in 2-wire con- figuration for triac applications or in 3-wire configuration for relay applications. The device consists of operational amplifiers, ...
Page 6
MODE MODE is a tri-state input pin for operation mode selection. See the following table 3. Override Control: The term “override” refers to the change of operating mode by switching the power switch twice within 3 seconds. When the ...
Page 7
Power On Initial The PIR signal amplifier requires a warm up period after power- on. The input should be disabled during this period. In the AUTO mode within the first 10 seconds of the initial time the chip allows ...
Page 8
Maximum Ratings (Above which the useful life may be impaired. For user guidelines, not tested) Storage Temperature ............................................................-40 Supply Voltage to Ground Potential (Inputs & V Supply Voltage to Ground Potential (Outputs & D/O Only) -0.3 to +6.0V DC ...
Page 9
AC Electrical Characteristics Voltage Regulator Sym Description V Output Voltage EE V Noninverting input of OP2 OP2P V Line Regulation V Load Regulation LDR I Regulator Output Current L Operational Amplifier and Window Comparator Sym Description BW 3dB Bandwidth ...
Page 10
Oscillator and ZC Input Pulse and Trigger Output Pulse Sym Description f Oscillator Frequency OSC t ZC Pulse Rise Time Pulse Fall Time Pulse Period Pulse Width ZW t TRIAC ...
Page 11
Typical Application Circuits Figure 11. Two-Wire Application Circuit of PT8A261 PT0075(04/03) PIR Sensor Light Switch Controller 11 Data Sheet PT8A261/262 Ver:5 ...
Page 12
Figure 12. Three-Wire Application Circuit of PT8A262 PT0075(04/03) PIR Sensor Light Switch Controller ON AUTO OFF 12 Data Sheet PT8A261/262 Ver:5 ...
Page 13
... Bering Drive, San Jose, California 95131, USA Tel: (1)-408-435 0800 Pericom Technology Incorporation reserves the right to make changes to its products or specifications at any time, without notice, in order to improve design or performance and to supply the best possible product. Pericom Technology does not assume any responsibility for use of any circuitry described other than the circuitry embodied in Pericom Technology product ...