b84143-g220-r11 EPCOS AG, b84143-g220-r11 Datasheet

no-image

b84143-g220-r11

Manufacturer Part Number
b84143-g220-r11
Description
3-line Filters Converters Power Electronics
Manufacturer
EPCOS AG
Datasheet
Power line filters for three-phase systems
Rated voltage 480/275 and 520/300 V~, 50/60 Hz
Rated current 8 to 220 A
Construction
s
s
s
Features
s
s
s
s
s
s
s
s
s
Applications
s
s
s
Terminals
s
s
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current,
rated temperature, date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
1) In accordance with IEC 60529:1989; EN 60529:1991; DIN VDE 0470-1
3-Line Filters
for Converters and Power Electronics
Three-line filter
Metal case
Book size
High insertion loss
Low leakage current
Optimized footprint saves space
Litz wires on the load side reduce mounting time
Low weight
Degree of protection: IP 20
Design based on
EN 133 200, CSA 22.2 No.8 1986
Optimized for long motor cables and operation under full load
UL 1283 approval for type -R110
for -R112 UL and CSA approval pending
Frequency converters for motor drives, e.g.
– elevators
– pumps
– traction systems
– conveyor systems
– HVAC systems (heating, ventilation and air conditioning)
Wind farms
Power supplies
Line: Safe-to-touch terminal blocks
Load: Litz wires
1)
,
239
03/01
B84143-G*-R110
B84143-G*-R112

Related parts for b84143-g220-r11

b84143-g220-r11 Summary of contents

Page 1

... Load: Litz wires Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, rated temperature, date code Minimum marking on packaging: Manufacturer’s logo, ordering code 1) In accordance with IEC 60529:1989; EN 60529:1991; DIN VDE 0470-1 , 239 03/01 B84143-G*-R110 B84143-G*-R112 ...

Page 2

... Filters for Converters and Power Electronics Typical circuit diagrams B84143-G8 … G20-R110/-R112 LINE B84143-G36 … G220-R110/-R112 LINE B84143-G*-R110 B84143-G*-R112 LOAD L1’ L2’ L3’ SSB1286-Z LOAD L1’ L2’ L3’ SSB1287-8 240 03/01 ...

Page 3

... V 25/100/21 (– 25 C/+ 100 C/21 days damp heat test) in accordance with EN 60068-1 R Approx. leak typ 1) typ. weight 1 1,3 16 5,2 2,8 16 2,4 3,3 16 1,8 4,4 16 1,2 4,9 16 1,0 7,5 16 0,7 8,0 16 0,4 11,5 241 03/01 B84143-G*-R110 B84143-G*-R112 Ordering code B84143-G8-R11* B84143-G20-R11* B84143-G36-R11* B84143-G50-R11* B84143-G66-R11* B84143-G90-R11* B84143-G120-R11* B84143-G150-R11* B84143-G220-R11* ...

Page 4

... Filters for Converters and Power Electronics Dimensional drawings B84143-G8-R11*, B84143-G20-R11* 50 Anschluss- Terminal 2 2 blocks 4 mm klemmen B84143-G36-R11* 60 Anschluss- Terminal 2 2 blocks 6 mm klemmen 300±10 200 Litz wire Litze L3’ L2’ ...

Page 5

... Filters for Converters and Power Electronics B84143-G50-R11* 60 Anschluss- Terminal 2 blocks klemmen B84143-G66-R11*, B84143-G90-R11* 80 Terminal Anschluss blocks 25 mm klemmen M10 300 500±10 Litz wire Litze 330 315±0,5 Marking LINE LOAD 300 500± ...

Page 6

... Filters for Converters and Power Electronics B84143-G120-R11*, B84143-G150-R11* 90 Terminal Anschluss- blocks klemmen M10 B84143-G220-R11* Anschlussklemmen 95 mm Terminal blocks 95 mm 110 PE M10 350 380 365±0,5 Marking LINE LOAD 2 2 Litz wire 400 430 415± ...

Page 7

... Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84143-G8-R11* 120 dB e 100 B84143-G36 … G220-R11* 120 dB e 100 B84143-G20-R11* SSB1288-G 120 ...

Page 8

... ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices ...

Related keywords