AS1110 AMSCO [austriamicrosystems AG], AS1110 Datasheet - Page 14

no-image

AS1110

Manufacturer Part Number
AS1110
Description
Constant-Current, 16-Channel LED Driver with Diagnostics
Manufacturer
AMSCO [austriamicrosystems AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AS1110
Manufacturer:
AMS
Quantity:
20 000
Part Number:
AS1110-BQFR
Manufacturer:
WORLDSEMI
Quantity:
12 000
Part Number:
AS1110-BSST
Manufacturer:
AMS
Quantity:
1 001
Part Number:
AS1110-BSSU
Manufacturer:
AMS
Quantity:
1 001
AS1110
Data Sheet - D e t a i l e d D e s c r i p t i o n
Detailed Open-LED Error Report
The detailed open-LED error report can be read out immediately after global error mode has been run. SDI must be 1
for the first device.
Figure 14. Detailed Open-LED Error Report Timing Diagram
Detailed Open-LED Error Report Example
Consider a case where three AS1110s are cascaded in one chain. A 1 indicates a LED is on, a 0 indicates a LED is off,
and an X indicates an open LED. The open-LED test is only applied to LEDs that are turned on. This test is used with
a test pattern where all LEDs are on at test time.
IC1:[1111111111111111] IC2:[111XX11111111X11] IC3:[1111111111111111]
IC2 has three open LEDs switched on due to input. 3*16 clock cycles are needed to write the entire error code out. The
detailed error report would look like this:
Comparing this report with the input data indicates that IC2 is the device with two open LEDs at position 4 and 5 and
one open LED at position 14. For such a test it is recommended to enter low-current diagnostic mode first
Current Diagnostic Mode on page 15)
This test can be used also on-the-fly without using an all 1s test pattern
Note: In an actual report there are no spaces in the output. LEDs turned off during test time cannot be tested and will
www.austriamicrosystems.com
For detailed timing information see
OEN
SDO
CLK
Failure Code: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
SDI
LD
LED Status: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Input Data: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
show a logic 1 in the detailed error report.
t
GSW(ERROR)
t
TESTING
T
Global Flag Readout
Flag
t
t
SU(ERROR)
GSW(ERROR)
t
P4
Timing Diagrams on page
t
SW(ERROR)
t
GSW(ERROR)
O
to reduce screen flickering.
Flag
9.
t
t
P4
H(L)
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 X X 1 1 1 1 1 1 1 1 X 1 1
1 1 1 0 0 1 1 1 1 1 1 1 1 0 1 1
DBit15
Revision 1.00
OBit15
DBit14
Detailed Error Report Readout
Open Error Report Output
OBit14
DBit13
OBit13
New Data Input
DBit12
OBit12
(see Figure 18 on page
DBitn
OBitn
DBit2
OBit2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
DBit1
OBit1
DBit0
OBit0
t
P1
17).
Don’t
Don’t
Care
Care
(see Low-
14 - 24