W25X10 WINBOND [Winbond], W25X10 Datasheet - Page 17

no-image

W25X10

Manufacturer Part Number
W25X10
Description
1M-BIT, 2M-BIT, 4M-BIT AND 8M-BIT SERIAL FLASH MEMORY WITH 4KB SECTORS AND DUAL OUTPUT SPI
Manufacturer
WINBOND [Winbond]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W25X10ALSN1G
Manufacturer:
WINBOND
Quantity:
14 000
Part Number:
W25X10ALSNIG
Manufacturer:
HYNIX
Quantity:
429
Part Number:
W25X10ALZPIG
Manufacturer:
WINBOND
Quantity:
14 000
Part Number:
W25X10AVSNIG
Manufacturer:
WINBOND
Quantity:
1 000
Part Number:
W25X10AVSNIG
Manufacturer:
WINBOND
Quantity:
1 000
Part Number:
W25X10AVSNIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Company:
Part Number:
W25X10AVSNIG
Quantity:
521
Part Number:
W25X10BLSNIG
Manufacturer:
ARTESYN
Quantity:
23
Part Number:
W25X10BVSNIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W25X10CLNIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W25X10CLSNIG
Manufacturer:
VISHAY
Quantity:
3 001
Part Number:
W25X10CLSNIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W25X10CLSNIG
0
Part Number:
W25X10CLSNIG-TR
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W25X10CLUXIG
0
W25X10, W25X20, W25X40, W25X80
10.2.5 Read Status Register (05h)
The Read Status Register instruction allows the 8-bit Status Register to be read. The instruction is
entered by driving /CS low and shifting the instruction code “05h” into the DIO pin on the rising edge of
CLK. The status register bits are then shifted out on the DO pin at the falling edge of CLK with most
significant bit (MSB) first as shown in figure 6. The Status Register bits are shown in figure 3 and
include the BUSY, WEL, BP2-BP0, TB and SRP bits (see description of the Status Register earlier in
this datasheet).
The Status Register instruction may be used at any time, even while a Program, Erase or Write Status
Register cycle is in progress. This allows the BUSY status bit to be checked to determine when the
cycle is complete and if the device can accept another instruction. The Status Register can be read
continuously, as shown in Figure 6. The instruction is completed by driving /CS high.
Figure 6. Read Status Register Instruction Sequence Diagram
Publication Release Date: September 22, 2006