0850-0004 EnerSys, 0850-0004 Datasheet

BATT CYCLON SLA 2V 8.0AH

0850-0004

Manufacturer Part Number
0850-0004
Description
BATT CYCLON SLA 2V 8.0AH
Manufacturer
EnerSys
Series
Cyclon®r
Datasheets

Specifications of 0850-0004

Voltage - Rated
2V
Capacity
8.0Ah
Size / Dimension
1.75" Dia x 3.94" H (44.5mm x 100.1mm)
Termination Style
Spade, .250" (6.3mm)
Rechargeability
Yes
Weight
1.1 lbs (498.95g)
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
842-1003
SELECTION GUIDE
1973 TO 2008
Publication No: US-CYC-SG-003 - June 2008

Related parts for 0850-0004

0850-0004 Summary of contents

Page 1

Publication No: US-CYC-SG-003 - June 2008 SELECTION GUIDE 1973 TO 2008 ...

Page 2

... EnerSys In addition to our manufacturing capability, EnerSys is proud to provide its customers with the following services: is the Applications Batteries from the EnerSys “pure lead” family are used in a wide variety of standby and portable/cyclic applications including those in: Value-Added Services ® Customized manufacturing design ...

Page 3

... TABLE OF CONTENTS Company background EnerSys ® .................................................................................................................... 2 Services and applications ......................................................................................... 2 Features and benefits ............................................................................................... 5 Technical information Capacity as a function of temperature ..................................................................... 7 State of charge .......................................................................................................... 7 Storage time as a function of temperature ............................................................... 7 Charging recommendations ...................................................................................... 7 CYCLON ® Battery Single Cells ® CYCLON product family .......................................................................................... 8 CYCLON ® battery alternate configurations .............................................................. 9 CYCLON ® ...

Page 4

... CYCLON battery provides leak-proof operation in any position. Steel can enclosure The CYCLON battery’s metal outer jacket offers extreme shock, vibration, temperature, and flammability protection. 4 www.enersys.com ® battery plates are extremely thin, One-piece plastic cover Direct thru-the-wall intercell connections ...

Page 5

... This is 50% to 100% overall better performance for your energy dollar. 7. Rugged construction - Due to their strong external packaging and internal pure lead composition, EnerSys products can withstand not only extreme temperatures but also harsh usage. CYCLON battery Single Cells are available housed in cases constructed of UL 94V-0 rated material ...

Page 6

... As a result, our batteries are more resistant to venting and dryout from continuous overcharge in standby applications. 8. Fastest recharge - EnerSys pure lead chemistry allows our batteries and cells to offer the highest recharge efficiency of any sealed-lead battery on the market. With pure lead, you can achieve a 95% ...

Page 7

... Battery Single Cells & Monoblocs ® 2.17 2.14 2.11 2.08 2.05 2.02 1.99 1.96 1.93 1. State of Charge, % Storage time as a function of temperature for CYCLON & Monoblocs (fully charged cell) www.enersys.com ® Battery Single Cells & RATE C/5 RATE 100 ® Battery Single Cells ...

Page 8

... Part charged cell Number mΩ @ 25°C charged cell D cell 2.5Ah 0810-0004 DT cell 4.5Ah 0860-0004 X cell 5.0Ah 0800-0004 E cell 8.0Ah 0850-0004 J cell 12.0Ah 0840-0004 BC cell 25Ah 0820-0004 CYCLON ® Battery 4V Monoblocs: Internal res. of fully charged short circuit Products Capacity Part Monobloc Number mΩ ...

Page 9

... Trapezoid BC Quick Disconnect Terminals AMP series 250 Faston terminals are available for BC batteries. Connection Terminations A wide variety of terminations are offered. For recommendations or to specify; contact your EnerSys Territory Manager or battery assembler. Fusible Links Flat Pack Specify your requirement. Dimensions .187” x .025” ...

Page 10

... CC should consult the EnerSys UL Recognized Component. Meets UL 1989 Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container Sealed-lead rechargeable battery must be recycled or disposed of properly. Contact EnerSys 10 www.enersys.com Varying lead lengths and gauges are also available; ...

Page 11

... CYCLON ® Battery 12 Volt 1x6 Shrink Wrap Product Number 0810-0108 0810-0109 0860-0108 0860-0109 0800-0108 0800-0109 0850-0108 0850-0109 CYCLON ® Battery 12 Volt 1x6 ABS Case Product Number 0810-0016 0810-0075 0800-0016 0800-0072 All dimensions, excluding weight, are maximum *Due to special assembly, consult the EnerSys www ...

Page 12

... All dimensions, excluding weight, are maximum UL Recognized Component. Meets UL 1989 Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container Sealed-lead rechargeable battery must be recycled or disposed of properly. Contact EnerSys 12 www.enersys.com DURATION 10 min 15 min ...

Page 13

... J cell 0.32 8.1 0.74 18.8 0.312 7.92 CYCLON Battery BC Single Cell mechanical specifications (F, G & Maximum) ® Products in cell 0.65 16.5 1.30 33.0 22 www.enersys.com DIMENSIONS in. mm in. mm in. mm 22° 0.27 6.9 0.025 0.64 2.41 61.2 22° 0.27 6.9 ...

Page 14

... CYCLON CYCLON 14 www.enersys.com Battery Single Cell constant current (CC) discharge ® Battery Single Cell constant power (CP) discharge ® Publication No: US-CYC-SG-003 - June 2008 ...

Page 15

... CC should consult the EnerSys ® Application Support Department. UL Recognized Component. Meets UL 1989 Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container Sealed-lead rechargeable battery must be recycled or disposed of properly. Contact EnerSys www.enersys.com DURATION 15 min 30 min ...

Page 16

... All dimensions, excluding weight, are maximum One-piece plastic cover High integrity terminal seal One-piece plastic case Lead grids 16 www.enersys.com Battery 4V/6V Monobloc standard assemblies ® ® Battery 4 Volt Monoblocs Length Description in. 0819-0010 4V, 2.5Ah Monobloc 3.13 0809-0010 4V, 5.0Ah Monobloc 3 ...

Page 17

... Battery 6V Monobloc mechanical specifications (A, B & maximum) Products A B in Monobloc 2.75 69.9 4.48 113.8 X Monobloc 3.02 76.7 5.48 139.2 E Monobloc 4.00 101.6 5.48 139.2 D Monobloc X & E Monobloc www.enersys.com DIMENSIONS in. mm in. mm in. 1.81 46.0 .61 15.5 1.23 2.12 53.8 .73 18.5 1.45 2.13 54.1 ...

Page 18

... Monobloc constant current (CC) curves to 1.67Vpc 4V/6V Monobloc constant power (CP) curves to 1.67Vpc 18 www.enersys.com Publication No: US-CYC-SG-003 - June 2008 ...

Page 19

... SINGLE CELL (sc) PART NUMBER DESCRIPTION 0810-0004 D Single Cell (Dsc) 0860-0004 DT Single Cell (DTsc) 0800-0004 X Single Cell (Xsc) 0850-0004 E Single Cell (Esc) 0840-0004 J Single Cell (Jsc) 0820-0004 BC Single Cell (BCsc) SINGLE CELL STANDARD BATTERY DESIGNS PART NUMBER DESCRIPTION 0810-0102 1x3 Dsc, double slot, shrink wrap ...

Page 20

... Xsc, Styrene case, leads 0850-0108 1x6 Esc, double slot, shrink wrap 0850-0109 1x6 Esc, shrink wrap, leads 0850-0114 2x3 Esc, double slot, shrink wrap 0850-0115 2x3 Esc, shrink wrap, leads 0820-0030 2x3 BCsc, double slot, copper strap MONOBLOC (mb) PART DESCRIPTION ...