FML
External Read Only Address: 0069
15
R3
Bit
15
14
13
12
11
10
9
8
7
6
5
4
FMU
14
R3
R3FMU
R2FMU
R1FMU
R3FML
R2FML
R1FML
Name
R3FU
R2FU
R1FU
R3FL
R2FL
R1FL
13
R3
FL
Table 40 - Reference Failure Status Register (RSR) Bits - Read Only
12
R3
FU
Reference 3 Multi-period Lower Limit Fail Bit
f the device sets this bit to high, the input REF3 fails the multi-period lower limit check.
(See Table 11, “Multi-Period Hysteresis Limits” on page 41)
Reference 3 Multi-period Upper Limit Fail Bit
If the device sets this bit to high, the input REF3 fails the multi-period upper limit
check. (See Table 11, “Multi-Period Hysteresis Limits” on page 41)
Reference 3 Single Period Lower Limit Fail Bit
If the device sets this bit to high, the input REF3 fails the single-period lower limit
check. (See Table 10, “Values for Single Period Limits” on page 40)
Reference 3 Single Period Upper Limit Fail Bit
If the device sets this bit to high, the input REF3 fails the single-period upper limit
check. (See Table 10, “Values for Single Period Limits” on page 40)
Reference 2 Multi-period Lower Limit Fail Bit
If the device sets this bit to high, the input REF2 fails the multi-period lower limit check.
(See Table 11, “Multi-Period Hysteresis Limits” on page 41)
Reference 2 Multi-period Upper Limit Fail Bit
If the device sets this bit to high, the input REF2 fails the multi-period upper limit
check. (See Table 11, “Multi-Period Hysteresis Limits” on page 41)
Reference 2 Single Period Lower Limit Fail Bit
If the device sets this bit to high, the input REF2 fails the single-period lower limit
check. (See Table 10, “Values for Single Period Limits” on page 40)
Reference 2 Single Period Upper Limit Fail Bit
If the device sets this bit to high, the input REF2 fails the single-period upper limit
check. (See Table 10, “Values for Single Period Limits” on page 40)
Reference 1 Multi-period Lower Limit Fail Bit
If the device sets this bit to high, the input REF1 fails the multi-period lower limit check.
(See Table 11, “Multi-Period Hysteresis Limits” on page 41)
Reference 1 Multi-period Upper Limit Fail Bit
If the device sets this bit to high, the input REF1 fails the multi-period upper limit
check. (See Table 11, “Multi-Period Hysteresis Limits” on page 41)
Reference 1 Single Period Lower Limit Fail Bit
If the device sets this bit to high, the input REF1 fails the single-period lower limit
check. (See Table 10, “Values for Single Period Limits” on page 40)
Reference 1 Single Period Upper Limit Fail Bit
If the device sets this bit to high, the input REF1 fails the single-period upper limit
check. (See Table 10, “Values for Single Period Limits” on page 40)
H
FML
R2
11
FMU
10
R2
R2
FL
9
Zarlink Semiconductor Inc.
ZL50019
FU
R2
8
68
FML
R1
7
Description
FMU
R1
6
R1
FL
5
R1
FU
4
FML
R0
3
FMU
R0
2
Data Sheet
R0
FL
1
R0
FU
0

Related parts for ZL50019