H3DK OMRON [Omron Electronics LLC], H3DK Datasheet - Page 3

no-image

H3DK

Manufacturer Part Number
H3DK
Description
Solid-state Timers
Manufacturer
OMRON [Omron Electronics LLC]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H3DK-A2ET380-440VAC
Manufacturer:
OMRON
Quantity:
5
Part Number:
H3DK-FA
Manufacturer:
OMRON
Quantity:
2
Part Number:
H3DK-FAC/DC24-240
Manufacturer:
OMRON
Quantity:
11
Part Number:
H3DK-HBSAC/DC24-240
Manufacturer:
OMRON
Quantity:
46
Part Number:
H3DK-HDS
Manufacturer:
OMRON
Quantity:
1
Specifications
■ Time Ranges
■ Ratings
Time range setting
Set time range
Scale numbers
Power supply voltage
Allowable voltage fluctuation
range
Power reset
Reset voltage
Voltage input
Power con-
sumption
Control output
Ambient operating temperature
Storage temperature
Ambient operating humidity
*3
H3DK-M2/-S2
H3DK-M1/-S1
H3DK-M2A/-S2A
H3DK-M1A/-S1A
*1
0.1 to 1.2 s
0.1 s
Minimum power-OFF time: 0.1 s
10% of rated voltage
At 240 VAC: 6.6 VA max.
At 240 VAC: 4.5 VA max.
At 12 VDC: 0.9 W max.
At 12 VDC: 0.6 W max.
Contact output, 5 A at 250 VAC with resistive load (cosφ = 1),
5 A at 30 VDC with resistive load
−20 to 55°C (with no icing)
−40 to 70°C (with no icing)
25% to 85%
• 24 to 240 VAC/DC, 50/60 Hz
• 12 VDC
• 24 to 240 VAC/DC: 85% to 110% of rated voltage
• 12 VDC: 90% to 110% of rated voltage
• 24 to 240 VAC/DC
• 12 VDC
High level: 20.4 to 264 VAC/DC, Low level: 0 to 2.4 VAC/DC
High level: 10.8 to 13.2 VDC, Low level: 0 to 1.2 VDC
*2
1 to 12 s
1 s
*4
*4
10 to 120 s
*2
10 s
*4, *5
1 to 12 min
1 min
12
10 to 120 min
10 min
*1.
*2.
*3.
*4.
*5.
*6.
When using a 24-VDC power supply voltage, there will
be an inrush current of approximately 0.25 A. Allow for
this inrush current when turning ON and OFF the
power supply to the Timer with device with a solid-
state output, such as a sensor.
DC ripple: 20% max.
The power consumption is for mode A after the Timer
times out.
For the H3DK-M@, the maximum power consumption
is given, including the current consumed by the input
circuit.
Refer to DC Power Consumptions (Reference Infor-
mation) on page 27 for DC power consumptions.
The control output ratings are for one H3DK operating
alone. If you operate two or more Timers side by side,
refer to Installation Pitch and Output Switching Capac-
ity (Reference Values) on the next page.
125 VDC: 0.15 A max. with resistive load, 125 VDC:
0.1 A with L/R of 7 ms.
Minimum load: 10 mA at 5 VDC (P level, reference
value)
1 to 12 h
1 h
H3DK-M/H3DK-S
10 to 120 h
10 h
100 to 1,200 h
100 h
3

Related parts for H3DK