PM6600 STMicroelectronics, PM6600 Datasheet - Page 40

IC LED DRIVR WHT BCKLT 24-VFQFPN

PM6600

Manufacturer Part Number
PM6600
Description
IC LED DRIVR WHT BCKLT 24-VFQFPN
Manufacturer
STMicroelectronics
Type
Backlight, White LEDr
Datasheet

Specifications of PM6600

Topology
PWM, Step-Up (Boost)
Number Of Outputs
6
Internal Driver
Yes
Type - Primary
Backlight
Type - Secondary
White LED
Frequency
200kHz ~ 1MHz
Voltage - Supply
4.7 V ~ 28 V
Voltage - Output
36V
Mounting Type
Surface Mount
Package / Case
24-VFQFN, 24-VFQFPN
Operating Temperature
-40°C ~ 85°C
Current - Output / Channel
32mA
Internal Switch(s)
Yes
Number Of Segments
60
Operating Supply Voltage
4.7 V to 28 V
Maximum Power Dissipation
2.3 W
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
For Use With
497-8414 - BOARD EVAL BASED ON PM6600
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Efficiency
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM6600
Manufacturer:
FUJITSU
Quantity:
2 402
Part Number:
PM6600
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
PM6600
Manufacturer:
ST
0
Part Number:
PM6600TR
Manufacturer:
ST
Quantity:
11 965
Part Number:
PM6600TR
Manufacturer:
st
Quantity:
5 145
Part Number:
PM6600TR
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
PM6600TR
Manufacturer:
ST
0
Part Number:
PM6600TR######
Manufacturer:
ST
0
Fault management
9.3
9.4
9.5
40/60
Open LED fault
In case a ROW is not connected or a LED fails open, the device has two different behaviors
according to the MODE pin status.
If the MODE pin is high (connected to AVCC), the open ROW is excluded from the control
loop and the device continues to work properly with the remaining ROWs, without asserting
the FAULT pin.
Connecting the MODE pin to SGND, the PM6600 behaves in a different manner: as soon as
one open ROW is detected, the FAULT pin is tied low. In case a second open ROW is
detected, the device is turned off. The internal logic latches this status: to restore the normal
operation, the device must be restarted by toggling the EN pin or performing a power on
reset (POR occurs when the voltage at the LDO5 pin falls below the lower UVLO threshold
and subsequently rises above the upper one).
As a consequence, If less than six ROWs are used in the application, the MODE pin must be
set high.
Shorted LED fault
When a LED is shorted, the voltage across the related current generator increases of an
amount equal to the missing voltage drop of the faulty LED. Since the feedback voltage on
each active generator is constantly compared with a fixed fault threshold V
the device detects the faulty condition and acts according to the MODE pin status.
In case the MODE pin is connected to AVCC, the PM6600 disconnects the ROWs whose
voltage is higher than the threshold and the FAULT pin is tied low. This option is also useful
to avoid undesired triggering of the shorted-LED protection simply due to the high voltage
drop spread across the LEDs.
If the MODE pin is low, when the voltage across one ROW is higher than V
threshold, the FAULT pin is set low and that ROW is disabled. If the voltage of a second
ROW becomes higher than V
latches this status until the EN pin is toggled or a POR is performed.
Intermittent connection
For intermittent connection it is intended the condition where the flat cable connector from
the leds backlight driver to the leds can have some issues on moving the panel of the
notebook. This kind of issue is represented as an intermittent connection, that means the
physical electrical connection between the ROWx pins of the PM6600 device and the White
LEDs can be open for a while.
The device will detect an open row fault.
There is one possible solution to determine whether the fault is due to the intermittent
connection or to a broken persistent electrical connection (open circuit). Since the device
disables the open rows during the intermittent connection, one possible solution is, on the
customer side, to toggle the EN pin and verify if the fault condition is still present.
In fact, once you disconnect one row, it will result as a off-row (Fault -> open row, latched).
When you connect it again, it is as a shorted led (Vrow higher than the threshold).
This is because the short led detection is still active.
TH,FAULT
Doc ID 14248 Rev 7
threshold, the device is turned off. The internal logic
TH,FAULT
TH,FAULT
PM6600
= 8.2 V,

Related parts for PM6600