HCPL-316J-500E Avago Technologies US Inc., HCPL-316J-500E Datasheet - Page 2

OPTOCOUPLER 2CH 2.5A 16-SOIC

HCPL-316J-500E

Manufacturer Part Number
HCPL-316J-500E
Description
OPTOCOUPLER 2CH 2.5A 16-SOIC
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-316J-500E

Configuration
High-Side
Package / Case
16-SOIC (0.300", 7.5mm Width)
Input Type
Differential
Delay Time
300ns
Current - Peak
2.5A
Number Of Configurations
1
Number Of Outputs
1
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 100°C
Mounting Type
Surface Mount
Fall Time
0.1 us
Rise Time
0.1 us
Isolation Voltage
3750 Vrms
Maximum Power Dissipation
1200 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
High Side Voltage - Max (bootstrap)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
516-1777-2
HCPL-316J-500E

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-316J-500E
Manufacturer:
AVAGO
Quantity:
3 200
Part Number:
HCPL-316J-500E
Quantity:
20 400
Part Number:
HCPL-316J-500E
Manufacturer:
AGILENT
Quantity:
17
Part Number:
HCPL-316J-500E
Manufacturer:
ST
0
Part Number:
HCPL-316J-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Part Number:
HCPL-316J-500E
0
Company:
Part Number:
HCPL-316J-500E
Quantity:
6 000
Company:
Part Number:
HCPL-316J-500E
Quantity:
3 400
Part Number:
HCPL-316J-500E/HCPL316J-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Typical Fault Protected IGBT Gate Drive Circuit
The HCPL-316J is an easy-to-use, intelligent gate driver
which makes IGBT V
able, and easy-to-implement. Features such as user con-
figurable inputs, integrated V
Figure 1. Typical desaturation protected gate drive circuit, noninverting.
Description of Operation during Fault Condition
1. DESAT terminal monitors the IGBT V
2. When the voltage on the DESAT terminal exceeds
3. FAULT output goes low, notifying the microcontroller
4. Microcontroller takes appropriate action.
V
X
X
Low
X
High
2
IN+
μC
D
7 volts, the IGBT gate voltage (V
lowered.
of the fault condition.
DESAT
R
.
F
V
X
X
X
High
Low
IN-
* THESE COMPONENTS ARE ONLY REQUIRED WHEN NEGATIVE GATE DRIVE IS IMPLEMENTED.
+
CE
UVLO
(V
Active
X
X
X
Not Active
CC2
fault protection compact, afford-
- V
1
2
3
4
5
6
7
8
E
)
V
V
V
GND1
RESET
FAULT
V
V
CE
IN+
IN-
CC1
LED1+
LED1-
detection, under volt-
Desat Condition
Detected on
Pin 14
X
Yes
X
X
No
CE
HCPL-316J
voltage through
OUT
) is slowly
V
DESAT
LED2+
V
V
OUT
CC2
V
V
V
V
EE
EE
E
C
Pin 6
(FAULT)
Output
X
Low
X
X
High
16
15
14
13
12
11
10
9
age lockout (UVLO), “soft” IGBT turn-off and isolated fault
feed back provide maximum design flexibility and circuit
protection.
Output Control
The outputs (V
trolled by the combination of V
IGBT Desat condition. As indicated in the below table, the
HCPL-316J can be configured as inverting or non-invert-
ing using the V
verting configuration is desired, V
and V
desired, V
UVLO is not active (V
go high, and the DESAT (pin 14) detection feature of the
HCPL-316J will be the primary source of IGBT protection.
UVLO is needed to ensure DESAT is functional. Once V
VLO+
12.4 V. Thus, the DESAT detection and UVLO features of
the HCPL-316J work in conjunction to ensure constant
IGBT protection.
> 11.6 V, DESAT will remain functional until V
IN-
*
toggled. When a non-inverting configuration is
IN-
V
Low
Low
Low
Low
High
R
OUT
PULL-DOWN
*
must be held low and V
IN+
OUT
C
BLANK
or V
100 Ω
and FAULT) of the HCPL-316J are con-
+
+
CC2
IN-
*
D
inputs respectively. When an in-
- V
+
DESAT
V
E
F
R
> V
G
IN
UVLO
, UVLO and a detected
IN+
), V
must be held high
IN+
OUT
toggled. Once
is allowed to
+
+
V
V
CE
CE
UVLO-
U-
<

Related parts for HCPL-316J-500E