BUK116-50L,118 NXP Semiconductors, BUK116-50L,118 Datasheet

TOPFET LOGIC LVL 50V D2PAK

BUK116-50L,118

Manufacturer Part Number
BUK116-50L,118
Description
TOPFET LOGIC LVL 50V D2PAK
Manufacturer
NXP Semiconductors
Series
TOPFET™r
Type
Low Sider
Datasheet

Specifications of BUK116-50L,118

Input Type
Non-Inverting
Number Of Outputs
1
On-state Resistance
22 mOhm
Current - Output / Channel
50A
Current - Peak Output
200A
Mounting Type
Surface Mount
Package / Case
D²Pak, TO-263 (4 leads + tab)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Operating Temperature
-
Other names
934044320118
BUK116-50L /T3
BUK116-50L /T3
Philips Semiconductors
DESCRIPTION
Monolithic temperature and
overload protected logic level power
MOSFET in a 5 pin surface
mounting plastic envelope, intended
as a general purpose switch for
automotive systems and other
applications.
APPLICATIONS
General controller for driving
FEATURES
PINNING - SOT426
July 1996
Logic level TOPFET
SMD version of BUK106-50L/S
PIN
mb
lamps
motors
solenoids
heaters
Vertical power DMOS output
stage
Low on-state resistance
Logic and protection supply
from separate pin
Low operating supply current
Overload protection against
over temperature
Overload protection against
short circuit load
Latched overload protection
reset by protection supply
Protection circuit condition
indicated by flag pin
5 V logic compatible input level
Separate input pin
for higher frequency drive
ESD protection on input, flag
and protection supply pins
Over voltage clamping for turn
off of inductive loads
Both linear and switching
operation are possible
1
2
3
4
5
input
flag
(connected to mb)
protection supply
source
drain
DESCRIPTION
QUICK REFERENCE DATA
FUNCTIONAL BLOCK DIAGRAM
PIN CONFIGURATION
PROTECTION SUPPLY
FLAG
INPUT
SYMBOL
V
I
P
T
R
SYMBOL
V
D
DS
tot
j
PSN
DS(ON)
1 2
3
4 5
PARAMETER
Continuous drain source voltage
Continuous drain current
Total power dissipation
Continuous junction temperature
Drain-source on-state resistance
PARAMETER
Protection supply voltage
Fig. 2.
1
mb
Fig.1. Elements of the TOPFET.
PROTECTION
LOGIC AND
BUK116-50S
BUK116-50L
SYMBOL
CLAMP
V
V
IS
IS
O/V
= 5 V
= 8 V
P
F
I
TOPFET
Product specification
BUK116-50L/S
Fig. 3.
P
NOM.
MAX.
125
150
50
50
35
28
10
5
D
S
POWER
MOSFET
SOURCE
DRAIN
Rev 1.000
UNIT
UNIT
m
m
˚C
W
V
A
V
V

Related parts for BUK116-50L,118

BUK116-50L,118 Summary of contents

Page 1

... FUNCTIONAL BLOCK DIAGRAM PROTECTION SUPPLY FLAG INPUT LOGIC AND PROTECTION Fig.1. Elements of the TOPFET. PIN CONFIGURATION Fig Product specification BUK116-50L/S MAX. UNIT 125 W 150 ˚ NOM. UNIT BUK116-50L 5 V BUK116-50S 10 V DRAIN O/V CLAMP POWER MOSFET SOURCE SYMBOL D TOPFET Fig. 3. Rev 1.000 ...

Page 2

... PSN = PSN CONDITIONS Human body model 250 pF 1.5 k the over temperature trip operates to protect the switch. j(TO) 2 Product specification BUK116-50L/S MIN. MAX 200 180 - 125 -55 150 - 150 - 250 For internal overload protection to remain latched while the control circuit is high, external series input resistance must be provided ...

Page 3

... T 85 ˚ 250 CONDITIONS ˚ CONDITIONS - CONDITIONS R = 100 ; 100 ; 300 0. 100 ; 100 ; 125 ˚ 300 s; 0. Product specification BUK116-50L/S MIN. MAX. UNIT - MIN. MAX. UNIT - 50 A MIN. TYP. MAX. UNIT - 0.8 1.0 K/W MIN. TYP. MAX. UNIT 0 100 Rev 1.000 ...

Page 4

... V; DS CONDITIONS normal operation or protection latched BUK116-50L BUK116-50S 150 ˚ 1. CONDITIONS 300 not applicable is less than V maximum. DS DSP 4 Product specification BUK116-50L/S Refer also to OVERLOAD PROTECTION LIMITING VALUES and INPUT CHARACTERISTICS. MIN. TYP. MAX 550 - - 0.4 - 150 - - MIN. TYP. MAX. 300 160 - IS MIN. ...

Page 5

... For waveforms see figure 28. L CONDITIONS CONDITIONS external overload protection strategy is possible using the flag pin to ‘tell’ the control circuit Product specification BUK116-50L/S MIN. TYP. MAX. 1.0 1.5 2.0 0 100 150 ˚ 150 ˚ > 100 - - MIN. TYP. ...

Page 6

... Over temperature detected SHORT CIRCUIT Overload condition detected SUPPLY FAULT Inadequate protection supply voltage CONDITIONS normal operation overload or fault BUK116-50L BUK116-50S mA = Product specification BUK116-50L/S FLAG LOGIC LOW LOGIC HIGH LOGIC HIGH LOGIC HIGH MIN. TYP. MAX. UNIT - 0.15 0 2.5 3 3.3 4 ...

Page 7

... Fig.8. Typical output characteristics f(V IS BUK116-50L 100 100 ms 0 100 ˚C Fig.9. Typical on-state characteristics Product specification BUK116-50L/S BUK116-50L 0.5 0.2 0.1 0.05 0. 1E-05 1E-03 1E- f(t); parameter j-mb p BUK116-50L/S VIS / VDS / parameter 250 s & BUK116-50L/S VIS / VDS / f(V ); parameter 250 1E+ ˚C. < ˚C. j Rev 1.000 ...

Page 8

... Fig.15. Normalised limiting overload dissipation 250 Product specification BUK116-50L/S a Normalised RDS(ON) = f(Tj) -60 -40 - 100 120 140 ˚ DS(ON) DS(ON BUK116-50L/S BUK116-50S BUK116-50L VPS / f(V ); conditions: V > 0.1 V j(TO -40 - 100 Tmb / =100 P /P (25 ˚C) = f(T DSM DSM DSM ...

Page 9

... IS mb SC(TO) BUK116-50L PDSM Fig.21. Typical clamping characteristics, 25 ˚ f(V PSP Product specification BUK116-50L/S BUK116-50L/S Energy / J Time / ms Tj(TO) - 100 140 180 Tmb / load DD PS PSN IS BUK116-50L/S BUK116-50L VIS / V = BUK116-50S VPS / V ); conditions parameter BUK116-50L/S typ. 60 VDS / V ); conditions 100 ; Rev 1.000 220 ˚ ...

Page 10

... Fig.26. Normalised limiting clamping energy ˚C j BUK116-50L/S VDS VIS Fig.27. Clamping energy test circuit Product specification BUK116-50L/S BUK116-50L/S 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 VSD / conditions 250 s SDS 100 120 Tmb / f(T ); conditions DSM mb D V(CL)DSR VDD + L VDS VPS + ...

Page 11

... Fig.31. Typical off-state leakage current ˚ f(T j DSR Ips normalised 1 0.5 -60 and R , Fig.32. Normalised protection supply current BUK116-50L/S Ciss Coss Crss iss oss rss 11 Product specification BUK116-50L/S Idsr typ 100 120 Conditions 100 . - 100 140 ˚ PSN 140 180 Rev 1.000 ...

Page 12

... Dimensions in mm July 1996 10.3 MAX 0.85 MAX (x4) Fig.33. SOT426 mounting base connected to centre pin (cropped short) 11.5 9.0 3.4 1.7 1.7 3.8 Fig.34. SOT426 soldering pattern for surface mounting. 12 Product specification BUK116-50L/S 4.5 MAX 1.4 MAX 0.5 17.5 1.3 (x4) Rev 1.000 ...

Page 13

... Philips customers using or selling these products for use in such applications their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale. July 1996 13 Product specification BUK116-50L/S Rev 1.000 ...

Related keywords