Z8F64220100ZDA Zilog, Z8F64220100ZDA Datasheet

ADAPTER ICE Z8 ENCORE 64K 64LQFP

Z8F64220100ZDA

Manufacturer Part Number
Z8F64220100ZDA
Description
ADAPTER ICE Z8 ENCORE 64K 64LQFP
Manufacturer
Zilog
Datasheets

Specifications of Z8F64220100ZDA

Module/board Type
*
For Use With/related Products
Z8 Encore!™
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3403
Z8 Encore! XP
The errata listed in
0344 to 0519, where the date code is YYWW (year and week of assembly). Date codes 0442 to 0519 are
mixed; the errata will apply to some units, but not others. These errata are NOT APPLICABLE to date
codes 0520 and later. When reviewing the following errata, it is recommended that you also download the
most recent version of the Product Specification.
Table 1. Z8 Encore! XP F64XX Series Errata Date Code 0344 to 0519
Sl
No. Summary
1
2
3
Read protect (RP)
option bit may be
bypassed.
START, STOP and
NAK bits in the I
control register can
be cleared by soft-
ware writing a 0 to
these bits.
Device may not com-
plete Stop Mode
Recovery initiated by
a general-purpose
input/output (GPIO)
pin transition.
Table 1
®
2
C
F64XX Series with Date Codes 0344 to 0519
UP006010-0508
are found in Zilog’s Z8 Encore! XP
Description
The RP option bit does not prevent Flash access when bypassing the Flash
controller. For more information, refer to Third Party Flash Programming Sup-
port for Z8 Encore!
User code cannot be read through the on-chip debugger when read protect is
enabled. User code can only be read out when bypassing the Flash controller.
Workaround
None
The START, STOP, and NAK bits in the I
software writing a 0 to these bits. The Product Specification states that they
cannot be cleared by writing a 0.
Workaround
None
When Stop Mode Recovery is initiated by a GPIO pin transition, multiple pin
transitions within 200 μs (approximate) of each other may cause the device to
only partially wake up from STOP mode. Therefore, the device idles in a state
between STOP mode and normal operation. The crystal oscillator is oscillat-
ing, but code does not execute.
When stuck in this idle state, assertion of the external RESET pin does not ini-
tiate a system reset.
Workaround
The workarounds are listed below:
Copyright ©2008 by Zilog
Add external filtering to the Stop Mode Recovery pin input signal to pre-
vent multiple transitions in less than 200 μs.
Enable the Watchdog Timer (WDT) in STOP mode to allow a WDT to
complete the Stop Mode Recovery in the event the device does not suc-
cessfully complete the Stop Mode Recovery initiated by the GPIO pin tran-
sition.
www.zilog.com
®
MCU Application Note (AN0117).
Product Update
Errata for Z8 Encore! XP
F64XX Series
®
, Inc. All rights reserved.
®
F64XX Series devices with date codes
2
C control register can be cleared by
®

Related parts for Z8F64220100ZDA

Z8F64220100ZDA Summary of contents

Page 1

... The errata listed in Table 1 are found in Zilog’s Z8 Encore! XP 0344 to 0519, where the date code is YYWW (year and week of assembly). Date codes 0442 to 0519 are mixed; the errata will apply to some units, but not others. These errata are NOT APPLICABLE to date codes 0520 and later ...

Page 2

Z8 Encore! XP F64XX Series with Date Codes Prior to 0344 The errata listed in Table 2 are found in the production Z8 Encore! XP codes prior to 0344, where the date code is YYWW (year and week of ...

Page 3

Table 2. Z8 Encore! XP F64XX Series Errata Date Coded Prior to 0334 (Continued) Sl No. Summary Description 4 UART address com- Setting bit 7 (MPMD[1]) of the UART control 1 register to 1 does not produce pare function does ...

Page 4

Table 2. Z8 Encore! XP F64XX Series Errata Date Coded Prior to 0334 (Continued) Sl No. Summary Description 11 RESET pin is not fil- The RESET pin does not properly filter the input signal. The device may enter tered. Reset ...

Page 5

... TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within this document has been verified according to the general principles of electrical and mechanical engineering. Z8, Z8 Encore!, and Z8 Encore! XP are registered trademarks of Zilog, Inc. All other product or service names are the property of their respective owners. ...