Z8F64220100ZDA Zilog, Z8F64220100ZDA Datasheet - Page 95

ADAPTER ICE Z8 ENCORE 64K 64LQFP

Z8F64220100ZDA

Manufacturer Part Number
Z8F64220100ZDA
Description
ADAPTER ICE Z8 ENCORE 64K 64LQFP
Manufacturer
Zilog
Datasheets

Specifications of Z8F64220100ZDA

Module/board Type
*
For Use With/related Products
Z8 Encore!™
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3403
PS019921-0308
2. Write to the Timer High and Low Byte registers to set the starting count value. This
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. If desired, enable the timer interrupt and set the timer interrupt priority by writing to
5. Configure the associated GPIO port pin for the Timer Input alternate function.
6. If using the Timer Output function, configure the associated GPIO port pin for the
7. Write to the Timer Control 1 register to enable the timer.
In COUNTER mode, the number of Timer Input transitions since the timer start is given
by the following equation:
PWM Mode
In PWM mode, the timer outputs a Pulse-Width Modulator (PWM) output signal through
a GPIO Port pin. The timer input is the system clock. The timer first counts up to the 16-
bit PWM match value stored in the Timer PWM High and Low Byte registers. When the
timer count value matches the PWM value, the Timer Output toggles. The timer continues
counting until it reaches the Reload value stored in the Timer Reload High and Low Byte
registers. Upon reaching the Reload value, the timer generates an interrupt, the count
value in the Timer High and Low Byte registers is reset to
If the TPOL bit in the Timer Control 1 register is set to 1, the Timer Output signal begins
as a High (1) and then transitions to a Low (0) when the timer value matches the PWM
value. The Timer Output signal returns to a High (1) after the timer reaches the Reload
value and is reset to
If the TPOL bit in the Timer Control 1 register is set to 0, the Timer Output signal begins
as a Low (0) and then transitions to a High (1) when the timer value matches the PWM
value. The Timer Output signal returns to a Low (0) after the timer reaches the Reload
value and is reset to
COUNTER Mode Timer Input Transitions
only affects the first pass in COUNTER mode. After the first timer Reload in
COUNTER mode, counting always begins at the reset value of
COUNTER mode the Timer High and Low Byte registers must be written with the
value
the relevant interrupt registers.
Timer Output alternate function.
Select either the rising edge or falling edge of the Timer Input signal for the count.
This also sets the initial logic level (High or Low) for the Timer Output alternate
function. However, the Timer Output function does not have to be enabled
0001H
.
0001H
0001H
.
.
=
Current Count Value Start Value
Z8 Encore! XP
0001H
Product Specification
and counting resumes.
0001H
®
F64XX Series
. Generally, in
Timers
81

Related parts for Z8F64220100ZDA