STEVAL-ISQ002V1 STMicroelectronics, STEVAL-ISQ002V1 Datasheet - Page 142

BOARD EVAL BASED ON ST72264G1

STEVAL-ISQ002V1

Manufacturer Part Number
STEVAL-ISQ002V1
Description
BOARD EVAL BASED ON ST72264G1
Manufacturer
STMicroelectronics
Datasheets

Specifications of STEVAL-ISQ002V1

Main Purpose
Interface, PMBus
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ST72F264
Primary Attributes
The PMBus™ Interface Using the ST7 I2C Peripheral
Secondary Attributes
Firmware in C Language
Product
Power Management Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6423

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-ISQ002V1
Manufacturer:
STMicroelectronics
Quantity:
1
ST72260Gx, ST72262Gx, ST72264Gx
EMC CHARACTERISTICS (Cont’d)
13.7.2 Electro Magnetic Interference (EMI)
Based on a simple application running on the
product (toggling 2 LEDs through the I/O ports),
the product is monitored in terms of emission. This
emission test is in line with the norm SAE J 1752/
3 which specifies the board and the loading of
each pin.
13.7.3 Absolute Maximum Ratings (Electrical
Sensitivity)
Based on three different tests (ESD, LU and DLU)
using specific measurement methods, the product
is stressed in order to determine its performance in
terms of electrical sensitivity. For more details, re-
fer to the application note AN1181.
Absolute Maximum Ratings
Notes:
1. Data based on characterization results, not tested in production.
142/172
Symbol
V
V
Symbol
ESD(HBM)
S
ESD(MM)
EMI
Peak level
Electro-static discharge voltage
(Human Body Model)
Electro-static discharge voltage
(Machine Model)
Parameter
Ratings
V
conforming to SAE J 1752/3
DD
=5V, T
Conditions
A
=+25°C,
T
T
A
A
=+25°C
=+25°C
13.7.3.1 Electro-Static Discharge (ESD)
Electro-Static Discharges (a positive then a nega-
tive pulse separated by 1 second) are applied to
the pins of each sample according to each pin
combination. The sample size depends on the
number of supply pins in the device (3 parts*(n+1)
supply pin). Two models can be simulated: Human
Body Model and Machine Model. This test con-
forms to the JESD22-A114A/A115A standard.
0.1MHz to 30MHz
30MHz to 130MHz
130MHz to 1GHz
SAE EMI Level
Frequency Band
Conditions
Monitored
Max vs. [f
8/4MHz
2.5
10
13
16
Maximum value
OSC
2000
200
16/8MHz
/f
13
24
31
4
CPU
]
1)
dBµV
Unit
Unit
-
V