R0K561622S000BE Renesas Electronics America, R0K561622S000BE Datasheet - Page 882

KIT STARTER FOR H8SX/1622

R0K561622S000BE

Manufacturer Part Number
R0K561622S000BE
Description
KIT STARTER FOR H8SX/1622
Manufacturer
Renesas Electronics America
Series
Renesas Starter Kits (RSK)r
Type
MCUr
Datasheets

Specifications of R0K561622S000BE

Contents
Board, Cables, CD, Debugger, Power Supply
Silicon Manufacturer
Renesas
Features
Coding And Debugging, E10A Emulator, RS232 Serial Connection
Kit Contents
Board
Silicon Family Name
H8SX/1622F
Silicon Core Number
R5F61622N50LGV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H8SX/1622
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Section 22 Flash Memory
(5)
The boot program will transfer the erasing program, and erase the user MATs and user boot MATs
in that order. On completion of this erasure, ACK will be returned and will enter the
programming/erasing state.
The host should select the device code, clock mode, and new bit rate with device selection, clock-
mode selection, and new bit-rate selection commands, and then send the command for the
transition to programming/erasing state. These procedures should be carried out before sending of
the programming selection command or program data.
Command
• Command, H'40, (one byte): Transition to programming/erasing state
Response
• Response, H'06, (one byte): Response to transition to programming/erasing state
Error Response
• Error response, H'C0, (one byte): Error response for user boot MAT blank check
• Error code, H'51, (one byte): Erasing error
(6)
A command error will occur when a command is undefined, the order of commands is incorrect,
or a command is unacceptable. Issuing a clock-mode selection command before a device selection
or an inquiry command after the transition to programming/erasing state command, are examples.
Error Response
• Error response, H'80, (one byte): Command error
• Command, H'xx, (one byte): Received command
Rev. 2.00 Sep. 16, 2009 Page 852 of 1036
REJ09B0414-0200
The boot program will send ACK when the user MAT and user boot MAT have been erased
by the transferred erasing program.
An error occurred and erasure was not completed.
Transition to Programming/Erasing State
Command Error
H'40
H'06
H'C0
H'80
H'51
H'xx