CF
SPECIFICATIONS
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
TYPICAL APPLICATIONS
• Power windows
• Auto door lock
• Electrically powered sunroof
• Electrically powered mirrors
• Powered seats
TYPES AND COIL DATA (at 20 C
* Other pick-up voltage types are also available. Please contact us for details.
Arrangement
Contact material
Initial contact resistance (Initial)
(By voltage drop 6 V DC 1 A)
Initial contact voltage drop
Rating
Expected
life (min.
ope.)
Nominal operating power
RoHS Directive compatibility information
and desired reliability level, therefore it is recommended to check this with the
actual load.
CF2-12V
Part No.
Order Discontinued as of October 31, 2009
http://www.nais-e.com/
Nominal switching
capacity
Max. carrying current
Min. switching capacity
Mechanical (at 120 cpm)
Electrical
22.5
.886
Nominal voltage,
resistive load
7 A 14 V DC,
Inrush 30 A
(Motor load)
20 A 14 V DC
(Motor lock)
V DC
12
16.5
.650
16.5
.650
#1
mm
Pick-up voltage,
30 A (2 minutes), 20 A (1 hour)
25 A (2 minutes), 15 A (1 hour)
• Lift gates
• Slide door closers, etc.
inch
Max. 7.2
(for DC motor forward/
reverse control circuits)
(Initial)
V DC
Ag alloy (Cadmium free)
1 Form C 2 (H bridge)
(coil applied voltage:
(coil applied voltage:
Max. 0.2 V (at 20 A)
N.O.: 20A 14 V DC
N.C.: 10A 14 V DC
Typ. 6 m
Typ. 9 m
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
12 V, at 20 C)
12 V, at 85 C)
1 A 12 V DC
Min.5 10
640 mW
Min.10
FEATURES
• 7 Amp Steady/30 Amp Inrush current
capability
• Simple footprint enables ease of PC
board layout
2 10
10
6
AUTOMOTIVE RELAY
5
(N.O.)
V DC (Initial)
(N.C.)
5
4
Drop-out
voltage,
Min. 1.0
68
TWIN POWER
F)
Coil resistance,
Characteristics
Remarks
*
*
*
*
*
*
*
*
ORDERING INFORMATION
Standard packing: Carton: 35pcs.; Case: 700pcs.
225 10%
Max. operating speed (at rated load)
Initial insulation resistance*
Initial
breakdown
voltage*
Operate time*
Release time*
Shock resistance
Vibration resistance
Conditions for operation,
transport and storage*
(Not freezing and
condensing at low
temperature)
Mass
1
2
3
4
5
6
7
8
Measurement at same location as “Initial breakdown voltage” section
Detection current: 10mA
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection time: 10 s
Half-wave pulse of sine wave: 6ms
Detection time: 10 s
Time of vibration for each direction;
Refer to Conditions for operation, transport and storage mentioned in AMBIENT
ENVIRONMENT.
Please inquire if you will be using the relay in a high temperature atmosphere
(110 C
X
Contact arrangement
230
2
Y
1 Form C
Z
F).
Between open contacts
Between contacts and coil
X, Y, direction: 2 hours
Z direction: 4 hours
3
3
Nominal operating
(at nominal voltage)
(at nominal voltage)
53.3 10%
Ex. CF
current,
mA
8
2
Common
Functional*
Destructive*
Functional*
Destructive*
Ambient temp.
Humidity
Standard type
1
CF RELAYS
2
operating Power,
4
6
–
5
7
Nominal
mW
640
Min. 100 M
Normally
Approx. 44.1 m/s2 {4.5 G},
Approx. 44.1 m/s
12 V
Min. 1,000 m/s
Coil voltage(DC)
Open
Space
Open
1,000 Vrms for 1 min.
1,000 Vrms for 1 min.
Approx. 15 g
Min. 100 m/s
5%R.H. to 85%R.H.
Max. 10 ms (initial)
Max. 10 ms (initial)
–40 F to +185 F
10 Hz to 100 Hz
10 Hz to 500 Hz
–40 C to + 85 C
12 V
120 cpm
Normally
Closed
Usable voltage
(at 500 V DC)
10 to 16
range,
2
2
VDC
.529 oz
2
{10 G}
{100 G}
{4.5 G},
Coil 1
Coil 2