LAA110 Clare, LAA110 Datasheet - Page 2

RELAY OPTOMOS 120MA DPST 8-DIP

LAA110

Manufacturer Part Number
LAA110
Description
RELAY OPTOMOS 120MA DPST 8-DIP
Manufacturer
Clare
Series
LAA, OptoMOS®r
Datasheet

Specifications of LAA110

Circuit
DPST (2 Form A)
Output Type
AC, DC
On-state Resistance
35 Ohm
Load Current
120mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 350 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
8-DIP (0.300", 7.62mm)
Load Voltage Rating
350 V
Load Current Rating
120 mA
Relay Type
Dual Pole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
CLA103

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAA110
Quantity:
6 110
Part Number:
LAA110
Manufacturer:
CPCLARE
Quantity:
5 510
Part Number:
LAA110
Manufacturer:
CPCLARE
Quantity:
20 000
Part Number:
LAA110CP
Manufacturer:
CPCLARE
Quantity:
5 510
Part Number:
LAA110CP
Manufacturer:
ATMEL
Quantity:
5 510
Part Number:
LAA110CP
Manufacturer:
N/A
Quantity:
20 000
Company:
Part Number:
LAA110CP
Quantity:
44
Part Number:
LAA110E
Quantity:
1 566
Part Number:
LAA110E
Manufacturer:
CPCLARE
Quantity:
20 000
LAA110
Absolute Maximum Ratings
Electrical absolute maximum ratings are at 25°C
Electrical Characteristics
2
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Input Power Dissipation
Total Power Dissipation
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
Parameter
Output Characteristics @ 25°C
Load Current, Continuous
Peak Load Current
On-Resistance
Off-State Leakage Current
Switching Speeds
Output Capacitance
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics @ 25°C
Input to Output Capacitance
1
2
1
Peak (10ms)
Turn-On
Turn-Off
Derate Linearly 1.33 mw/˚C
Derate Linearly 6.67 mw/˚C
If both poles operate the load current must be derated so as not to exceed the package power dissipation value.
2
1
1
-40 to +125
-40 to +85
Ratings
3750
350
150
800
50
5
1
Units
mW
mW
V
mA
V
°C
°C
V
A
rms
I
I
P
F
F
Conditions
=5mA, V
=5mA, V
50V; f=1MHz
I
I
L
V
L
t=10ms
I
=120mA
=120mA
www.clare.com
V
L
F
=5mA
=350V
R
=5V
-
-
-
L
L
=10V
=10V
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Symbol
I
C
T
I
R
C
T
LEAK
LPK
V
I
I
OUT
I
OFF
ON
-
ON
R
I/O
L
F
F
Min
0.4
0.9
-
-
-
-
-
-
-
-
-
-
Typ
0.7
1.2
25
25
3
-
-
-
-
-
-
-
Max
120
350
1.4
35
10
1
3
3
5
-
-
-
Units
mA
mA
mA
mA
μA
ms
ms
μA
pF
pF
Ω
V
R09

Related parts for LAA110