VPP12-2400 Triad Magnetics, VPP12-2400 Datasheet

TRANSF 6.3VAC 4.8A WORLD SERIES

VPP12-2400

Manufacturer Part Number
VPP12-2400
Description
TRANSF 6.3VAC 4.8A WORLD SERIES
Manufacturer
Triad Magnetics
Series
PC Mount: World Series™r
Type
Dual Primaryr
Datasheets

Specifications of VPP12-2400

Maximum Power
30 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
12.6 VAC @ 2.4A
Parallel Output Voltage @ Current
6.3 VAC @ 4.8A
Mounting Type
Through Hole
Power Rating
30 VA
Product
World Series Transformers
Mounting Style
SMD/SMT
Dimensions
2.187 in L x 2.625 in W x 1.562 in H
Height
1.562 in
Length
2.187 in
Termination Style
Solder
Width
2.625 in
Transformer Type
Power
Input Voltage
115V
Output Voltage
12.6V
Current Rating
4.8A
Transformer Mounting
PC Board
Secondary Current Nom
4.8A
Primary Voltages
115 / 230V
Rohs Compliant
Yes
Secondary Voltages
2 X 6.3V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
237-1075
VPP12–2400
Electrical Specifications (@25C)
1. Maximum Power: 30.0VA
2. Input: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz
3. Output: Series
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 30C TYP (45C MAX allowed)
6. Insulation Resistance: 100MΩ
7. Hipot: 4000VAC between primary to secondary and windings to core.
8. Recommended Fuse
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds
U
Safety:
Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required.
W
Agency File:
UL: File E53148, UL 5085-1 and 3 (formerly UL 506), General Purpose.
UL: File E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
TUV: File R 72072385, EN 60950, (IEC950) information Technology Equipment.
A. Dimensions:
B. PIN DIM. : 0.045 SQ
C. WT Lbs. : 1.15
D. Mounting Holes: 0.156 dia. x 4
Connections
Input:
Output:
RoHS Compliance: Meets the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for
the most current version.
1
2
3
4
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
Non-Inherently limited. Class 2 not wet, Class 3 wet.
Non-Inherently limited. Class 2.
Fuse must be used on secondary as conditions of acceptability for UL Class2/3 operation.
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
L flammability requirements.
1.562
orld Series Transformers are designed and manufactured to meet the following agency approvals:
H
Series – Pin 7 to Pin 12, Jumper Pin 9 to Pin 10
Parallel – Pin 1 to Pin 6, Jumper Pin 1 to Pin 4 and Pin 3 to Pin 6
Parallel – Pin 7 to Pin 12, Jumper Pin 7 to Pin 10 and Pin 9 to Pin 12
Series – Pin 1 to Pin 6, Jumper Pin 4 to Pin 3
2.625
W
Series: Littelfuse p/n 313 2.5HXP, 2.5A 250V, slow blow, ¼ x 1 ¼ or,
Parallel: Littelfuse p/n 313 5.0HXP, 5A 250V, slow blow, ¼ x 1 ¼ or,
4
:
1
: 12.6V CT@ 2.4A; Parallel
2.187
Cooper Bussmann p/n BKMDL-2 ½, 2.5A 250V, ¼ x 1 ¼
Cooper Bussmann p/n BKMDL-5, 5A 250V, ¼ x 1 ¼
D
3
:
0.550
A
0.275
B
22520B Temescal Canyon Road
Corona, California
92883
2
1.680
: 6.3V @ 4.8A
C
ML
-
1.75
Units: In inches
MD
2.187
P
P C M
MW
O W E R
O U N T :
T
Publish Date: August 3, 2009
R A N S F O R M E R
W
O R L D
6
4
3
1
SCHEMATIC
S
E R I E S
12
10
9
7

Related parts for VPP12-2400

Related keywords