BK/HLR Cooper/Bussmann, BK/HLR Datasheet

FUSEHOLDER 12A 300V FAST NON-REJ

BK/HLR

Manufacturer Part Number
BK/HLR
Description
FUSEHOLDER 12A 300V FAST NON-REJ
Manufacturer
Cooper/Bussmann
Series
HLRr
Type
Holderr
Datasheet

Specifications of BK/HLR

Fuse Size
GLR
Number Of Circuits
1
Mounting Type
Panel Mount
Termination Style
Wire Leads
Voltage
300V
Current Rating
15A
Voltage Rating Vac
300V
Fuse Current
15A
Fuse Holder Type
Fuse Holder
Holder Terminals
Wire Leads
No. Of Fuses
1
Wire Size (awg)
18
Fuse Type
Fast Acting
Product
Holder
Voltage Rating
300 Volts
Mounting Style
Panel
Size (lxwxh)
2.2 in x 0.85 in x 0.85 in
For Use With
BAF-25 - FUSE 250V 25A FERRULE FAST ACTBAF-5 - FUSE 250V 5AMP FERRULE FAST ACTBAF-4 - FUSE 250V 4AMP FERRULE FAST ACTBAF-3 - FUSE 250V 3AMP FERRULE FAST ACTBAF-2 - FUSE 250V 2AMP FERRULE FAST ACT
Lead Free Status / RoHS Status
Lead free / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS non-compliant, Lead free / RoHS Compliant
Other names
BK-HLR
HLR
Catalog Symbol: GLR (Fuse) HLR (Fuseholder)
Fast-Acting, Non-Rejection Style Fuse
Ampere Rating: ‹Ω ¡ §-15 Amperes
Voltage Rating: 300 Volts AC or less
Interrupting Rating: 10,000 Amperes
Agency Information:
GLR Fuse:
UL Listed, Std. 248-14
‹Ω ¡ §-15A/300 Vac, Guide JDYX, File E19180
CSA Certified, C22.2 No. 248.14, 0-10A/300 Vac
Class 1422-01, File 53787
HLR Fuseholder:
UL Recognized, 12A, 300 Vac, Guide IZLT2, File E14853
CSA Certified, 12A, 300 Vac, Class 6225-01, File 47235
HLR-2A:
UL Recognized, 15A, 300 Vac, Guide IZLT2, File E14853
CSA Certified, 15A, 300 Vac, Class 6225-01, File 47235
Electrical Ratings for Type GLR Fuses and Non-Rejection
Style Carriers
Fuse
GLR-‹Ω ¡ §
GLR-⁄Ω ™
GLR-1
GLR-1⁄Ω ™
GLR-1flΩ ¡ º
GLR-2
GLR-3
GLR-4
General Information:
• HLR carrier comes with 6∑ of #18 red insulated solid copper wire
• Customer inserts a #18 insulated solid copper wire into load side
• Order part number HLR-2A to obtain 6∑ of #18 black insulated solid
• Order part number HLR-2L to obtain 6∑ of #18 black insulated solid
• An alternative to the HLR fuseholder is the A fuseholder. The A
• Fuse and knob are an integral one-piece unit. There are no
• Units can be panel mounted with a separate steel clip. For the
• Do not put tension on line (rear) terminal of fuse-holder.
Specialty Fuse
Fast-Acting, Non-Rejecting
5-22-02
knockout hole (see above), choose #BK/A-104. For the keyhole
punch type hole, choose #6374 for panels .043” to .062” thick, or
#4909 for panels .030” to .042” thick.
attached to the line side.
receptacle.
copper wire pre-installed in a load side receptacle.
copper wire packaged loose (un-installed).
fuseholder comes WITHOUT leads. The customer inserts #18
insulated solid copper wire into the line side receptacle as well as into
the load side receptacle. It has the same body dimensions, utilizes the
same mounting hole, and takes the same mounting clips as the HLR.
The A fuseholder is UL Recognized, 10A, 300Vac, Guide IZLT2, File
E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
replacement knobs (caps).
SB02233
Carrier
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
Fuse
GLR-5
GLR-6
GLR-7
GLR-8
GLR-9
GLR-10
GLR-12
GLR-15
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.
Carrier
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR-2A
The only controlled copy of this Data Sheet is the electronic read-only version located on the
Bussmann Network Drive. All other copies of this document are by definition uncontrolled.
This bulletin is intended to clearly present comprehensive product data and provide technical
information that will help the end user with design applications. Bussmann reserves the right,
without notice, to change design or construction of any products and to discontinue or limit
distribution of any products. Bussmann also reserves the right to change or update, without
notice, any technical information contained in this bulletin. Once a product has been selected,
it should be tested by the user in all possible applications.
FUSE AND CARRIER
MOUNTING HOLE
Time-Current Characteristic Curves–Average Melt
Dimensional Data
FUSE
100
.01
10
.1
18.29mm
1
18.80mm
.720''
(15.9mm)
.740''
0.63"
Knockout Hole
22.10mm
21.59mm
.870''
.850''
CURRENT IN AMPERES
21.59mm
.850''
Keyhole Punch
57.15mm
2.250''
10.41mm
C L
.410''
6.48mm
16.13mm
.255''
.635''
AMPERE
RATING
Bussmann
Form No. GLR & HLR
& HLR
Data Sheet: 2032
Load Lead
GLR
Line Lead
Page 1 of 1
®