LK16085R6K-T Taiyo Yuden, LK16085R6K-T Datasheet - Page 12

INDUCTOR 5.6UH 10% 0603 SMD

LK16085R6K-T

Manufacturer Part Number
LK16085R6K-T
Description
INDUCTOR 5.6UH 10% 0603 SMD
Manufacturer
Taiyo Yuden
Series
LKr
Datasheet

Specifications of LK16085R6K-T

Inductance
5.6µH
Current
5mA
Tolerance
±10%
Shielding
Shielded
Dc Resistance (dcr)
1.55 Ohm Max
Q @ Freq
35 @ 4MHz
Self Resonant Freq
22MHz
Package / Case
0603 (1608 Metric)
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 85°C
Frequency - Test
4MHz
Applications
Portable Equipment
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Saturation
-
Current - Temperature Rise
-
Other names
587-1587-2
LK16085R6K-T

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LK16085R6K-T
Manufacturer:
TAIYO YUDEN
Quantity:
66 000
Part Number:
LK16085R6K-T
Manufacturer:
BSE
Quantity:
239
Multilayer chip inductors and beads
14. Damp Heat
15. Loading under
16. Loading at High
Note on standard condition: "standard condition" referred to herein is defined as follows:
5 to 35℃ of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20 ± 2℃ of temperature, 60 to 70% relative hu-
midity, and 86 to 106kPa of air pressure. Unless otherwise specified, all the tests are conducted under the "standard condition."
(Steady state)
RELIABILITY DATA
Temperature
Damp Heat
当社カタログをご使用の際には 「当社製品に関するお断り」 を必ずお読みください。
Item
Appearance :No significant abnormality.
Impedance change:Within ±30%
Appearance :No significant abnormality.
Impedance change:Within ±30%
Appearance :No significant abnormality.
Impedance change:Within ±30%
BK0603 BK1005 BK1608 BK2125
BK2010 BK3216
ARRAY
BKP0603 BKP1005 BKP1608 BKP2125 CK1608 CK2125 CKP2520 LK1005
Specified Value
No
mechanical
damage.
Inductance
change:
Within ±20%
Q change:
Within ±30%
No
mechanical
damage.
Inductance
change:
Within ±20%
Q change:
Within ±30%
No
mechanical
damage.
Inductance
change:
Within ±20%
Q change:
Within ±30%
No
mechanical
damage.
Inductance
change :
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±30%
No mechani-
cal damage.
Inductance
change:
Within
±10%
Q change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±10%
Q
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±10%
Q
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
0.047 to
12.0μH:
Within
±10%
15.0 to
33.0μH:
Within
±15%
Q
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
0.047 to
12.0μH:
Within
±10%
15.0 to
33.0μH:
Within
±15%
Q
change:
Within
±30%
LK1608
No
mechanical
damage.
Inductance
change:
Within
±20%
Q change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±20%
Q
change:
Within
No
mechanical
damage.
Induc-
tance
change:
Within
±20%
Q
change:
Within
±30%
±30%
LK2125
No mechanical damage.
Inductance change:Within ±10%
Q change:Within ±20%
No mechanical damage.
Inductance change:Within ±10%
Q change:Within ±20%
No mechanical damage.
Inductance change:Within ±10%
Q change:Within ±20%
HK0603
HK1005
Please read the "Notice for TAIYO YUDEN products" before using this catalog.
HK1608
HK2125 HKQ0603S AQ105
(Note 1)
measurement shall be made after 48 ± 2 hrs of
recovery under the standard condition.
BBK Series:
Temperature:40±2℃
Humidity:90 to 95%RH
Duration:500
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
LK、 CK、 CKP、 HK、 HKQ、 AQ Series:
Temperature:40±2℃ (LK、 CK 、 CKPSeries)
Humidity:90 to 95%RH
Duration:500±12 hrs
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
BK Series:
Temperature:40±2℃
Humidity:90 to 95%RH
Duration:500
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
LK、 CK、 CKP、 HK、 HKQ、 AQ Series:
Temperature:40±2℃ (LK、 CK 、 CKPSeries)
Humidity:90 to 95%RH
Duration:500±12 hrs
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
BK Series:
Temperature:125±3℃
Applied current:Rated current
Duration:500
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
LK、 CK、 CKP、 HK、 HKQ、 AQ Series、 BK Series
P type:
Temperature:85±2℃ (LK、 CK 、 CKPSeries)
temperature range -55 to +85℃)
Applied current:Rated current
Duration:500±12 hrs
Recovery:2 to 3 hrs of recovery under the
standard condition after the test. ( See Note 1)
:85±3℃ (BK Series P type)
:85±2℃ (HK1608, 2125)
:85±2℃ (HK1005, AQ105 operating
:125±2℃ (HK0603, HK1005, HKQ0603S,
AQ105 operating temperature range -55 to +125℃)
Test Methods and Remarks
:60±2℃ (HK、 HKQ、 AQ Series)
:60±2℃ (HK、 HKQ、 AQ Series)
+24
−0
+24
−0
+24
−0
hrs
hrs
hrs
4/4
253
5

Related parts for LK16085R6K-T