SAF-XC164CM-16F20F BA Infineon Technologies, SAF-XC164CM-16F20F BA Datasheet - Page 43

no-image

SAF-XC164CM-16F20F BA

Manufacturer Part Number
SAF-XC164CM-16F20F BA
Description
IC MCU 16BIT FLASH 64-LQFP
Manufacturer
Infineon Technologies
Series
XC16xr
Datasheet

Specifications of SAF-XC164CM-16F20F BA

Core Processor
C166SV2
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SPI, UART/USART
Peripherals
PWM, WDT
Number Of I /o
47
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.35 V ~ 2.7 V
Data Converters
A/D 14x8/10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-LFQFP
For Use With
B158-H8961-X-X-7600IN - KIT EASY XC164CMXC164CMUCANIN - KIT U-CAN STARTER XC164CM
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Other names
SP000244707
XC164CM
Derivatives
Functional Description
3.14
Watchdog Timer
The Watchdog Timer represents one of the fail-safe mechanisms which have been
implemented to prevent the controller from malfunctioning for longer periods of time.
The Watchdog Timer is always enabled after a reset of the chip, and can be disabled
until the EINIT instruction has been executed (compatible mode), or it can be disabled
and enabled at any time by executing instructions DISWDT and ENWDT (enhanced
mode). Thus, the chip’s start-up procedure is always monitored. The software has to be
designed to restart the Watchdog Timer before it overflows. If, due to hardware or
software related failures, the software fails to do so, the Watchdog Timer overflows and
generates an internal hardware reset.
The Watchdog Timer is a 16-bit timer, clocked with the system clock divided by
2/4/128/256. The high byte of the Watchdog Timer register can be set to a prespecified
reload value (stored in WDTREL) in order to allow further variation of the monitored time
interval. Each time it is serviced by the application software, the high byte of the
Watchdog Timer is reloaded and the low byte is cleared. Thus, time intervals between
13 μs and 419 ms can be monitored (@ 40 MHz).
The default Watchdog Timer interval after reset is 3.28 ms (@ 40 MHz).
Data Sheet
41
V1.4, 2007-03

Related parts for SAF-XC164CM-16F20F BA