MAX6466XR16+T Maxim Integrated Products, MAX6466XR16+T Datasheet - Page 5

IC VOLT DETECTOR LP SC70-3

MAX6466XR16+T

Manufacturer Part Number
MAX6466XR16+T
Description
IC VOLT DETECTOR LP SC70-3
Manufacturer
Maxim Integrated Products
Type
Simple Reset/Power-On Resetr
Datasheet

Specifications of MAX6466XR16+T

Number Of Voltages Monitored
1
Output
Open Drain or Open Collector
Reset
Active Low
Reset Timeout
150 ms Minimum
Voltage - Threshold
1.6V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
SC-70-3, SOT-323-3
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MAX6466XR16+T
MAX6466XR16+TTR
SOT23-3
R1
R2
R3
1
2
3
MAX6461–MAX6466
SC70-3
PIN
1.23V
2
1
3
_______________________________________________________________________________________
Ultra-Low-Power Voltage Detectors and
SOT23-5
V
CC
Functional Diagram
2, 3
4
5
1
TIMEOUT
RESET
NAME
GND
MAX6461–
OUT
OUT
N.C.
V
MAX6466
CC
OUTPUT
STAGE
Detector Output for the MAX6461/MAX6462/MAX6463: Push-pull (active-low or
active-high) and open-drain (active-low) options. OUT is asserted low when the
monitored input (V
until the monitored input exceeds the internal V
high when the monitored input (V
remains high until the monitored input exceeds the internal V
open-drain output OUT requires an external pullup resistor. Output for the
MAX6464/MAX6465/MAX6466: Push-pull (active-low or active-high) and open-
drain (active-low) options.
OUT is asserted low when the monitored input (V
V
exceeds the internal V
input (V
150ms after the monitored input exceeds the internal V
drain output OUT requires an external pullup resistor.
Ground. In the SOT23-5 package, both pins must be grounded.
Supply Voltage and Monitored Voltage Input
No Connection
TH-
threshold and remains low for at least 150ms after the monitored input
OUT
CC
) drops below the internal V
µP Supervisory Circuits
CC
The MAX6461/MAX6462/MAX6463 voltage detectors
and the MAX6464/MAX6465/MAX6466 µP reset supervi-
sory circuits monitor battery, power-supply, and system
voltages from +1.6V to +5.5V. These devices consume
only 1µA of supply current with a 3.6V supply voltage.
Whenever V
the output is asserted and remains asserted until V
rises above V
±2.5% threshold accuracy over temperature and offer
protection to short voltage transients. These devices are
ideal for low-cost and space-critical applications
because they do not require external components for
proper operation.
) drops below the internal V
TH+
threshold. OUT is asserted high when the monitored
CC
CC
TH+
FUNCTION
) drops below the internal V
falls below the internal V
TH-
(V
threshold and remains high for at least
TH+
Detailed Description
= V
TH+
TH-
CC
TH
threshold. OUT is asserted
) drops below the internal
threshold and remains low
- × 1.05). All devices have
Pin Description
TH+
threshold. The open-
TH+
TH-
threshold. The
TH
threshold and
- threshold,
CC
5

Related parts for MAX6466XR16+T