Specifications of ADM691AR

Rohs Status
RoHS non-compliant
Number Of Voltages Monitored
1
Output
Open Drain, Push-Pull
Reset
Active High/Active Low
Reset Timeout
35 ms Minimum
Voltage - Threshold
4.65V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-SOIC (0.300", 7.5mm Width)
Number Of Elements
1
Monitored Voltage 1 (typ)
4.75 to 5.5V
Threshold Voltage 1 (max)
4.73V
Battery Backup Switching
Yes
Watchdog Timer
Yes
Chip Enable Signals
Yes
Reset Active Time
70ms
Manual Reset
No
Package Type
SOIC
Operating Supply Voltage (min)
4.75V
Operating Supply Voltage (max)
5.5V
Reset Threshold Voltage (max)
4.73V
Reset Threshold Voltage (min)
4.5V
Family Name
ADM691
Power Dissipation
600mW
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Power Fail Detection
Yes
Mounting
Surface Mount
Pin Count
16
Supply Current
1.95mA
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM691AR
Manufacturer:
AD
Quantity:
5 530
Part Number:
ADM691AR
Manufacturer:
AD
Quantity:
1 000
Part Number:
ADM691AR
Manufacturer:
AD
Quantity:
1 000
Part Number:
ADM691AR
Manufacturer:
AD
Quantity:
1 000
Part Number:
ADM691AR
Manufacturer:
AD
Quantity:
1 000
Part Number:
ADM691AR
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADM691AR
Quantity:
19
Part Number:
ADM691AR-REEL
Manufacturer:
NXP
Quantity:
330
Part Number:
ADM691AR-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM691ARZ
Manufacturer:
AMD
Quantity:
6 219
Part Number:
ADM691ARZ
Manufacturer:
AD
Quantity:
2 952
Part Number:
ADM691ARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADM691ARZ-REEL7
Quantity:
2 353
(V
ADM691A/ADM693A/ADM800L/M–SPECIFICATIONS
Parameter
BATTERY BACKUP SWITCHING
RESET AND WATCHDOG TIMER
POWER FAIL DETECTOR
CC
V
V
V
V
V
Supply Current (Excludes I
Supply Current in B. Backup (Excludes I
Battery Standby Current
Battery Switchover Threshold
V
Battery Switchover Hysteresis
BATT ON Output Voltage Low
BATT ON Output Short Circuit Current
Reset Voltage Threshold
Reset Threshold Hysteresis
V
LOW LINE to RESET Delay
Reset Timeout Period Internal Oscillator
Reset Timeout Period External Clock
Watchdog Timeout Period, Internal Oscillator
Watchdog Timeout Period, External Clock
Minimum WDI Input Pulse Width
RESET Output Voltage
RESET Output Short Circuit Current
RESET Output Voltage Low
LOW LINE Output Voltage
LOW LINE Short Circuit Source Current
WDO Output Voltage
WDO Short Circuit Source Current
WDI Input Threshold
WDI Input Current
PFI Input Threshold ADM69xA
PFI Input Threshold ADM800L/M
PFI Input Current
PFO Output Voltage
PFO Short Circuit Source Current
PFI to PFO Delay
= 4.75 V to 5.5 V (ADM691A, ADM800L) 4.5 V to 5.5 V (ADM693A, ADM800M) V
CC
OUT
CC
OUT
BATT
CC
CC
(+ = Discharge, – = Charge)
ADM691A, ADM800L
ADM693A, ADM800M
ADM800L, V
ADM800M, V
Logic Low
Logic High
, V
–V
to V
to RESET Delay
Output Voltage
in Battery Backup Mode
to V
BATT
BATT
OUT
OUT
Operating Voltage Range
Output Resistance
Output Resistance
CC
CC
Falling
Falling
OUT
)
OUT
)
Min
0
V
V
V
V
V
–0.1
–1.0
1
4.5
4.25
4.55
4.3
140
1.0
70
100
3.5
0.1
3.5
1
3.5
0.75
–50
1.2
1.225
3.5
1
CC
CC
BATT
BATT
BATT
– 0.05
– 0.3
– 0.25
– 0.15
V
– 0.3
CC
–2–
Typ
V
V
0.8
70
0.04
V
V
60
0.1
0.7
60
15
4.65
4.40
15
80
800
200
2048
1.6
100
4096
1024
0.004
0.1
7
0.4
15
3
–10
20
1.25
1.25
15
25
60
0.01
CC
CC
BATT
BATT
– 0.02
– 0.2
+ 0.03
– 0.03
BATT
= +2.8 V, T
Max
5.5
1.2
12
20
25
100
1
+0.02
+0.02
0.4
1.5
100
4.75
4.50
4.70
4.45
280
2.25
140
0.3
0.4
20
0.4
100
0.4
10
0.8
50
1.3
1.275
0.4
100
25
A
= T
Unit
V
V
V
V
V
V
V
V
mV
V
V
mA
V
V
V
V
mV
ns
ms
Cycles
s
ms
Cycles
Cycles
ns
V
V
V
mA
V
V
V
V
V
mA
V
V
V
V
nA
V
A
A
A
A
A
s
A
A
A
A
s
s
MIN
to T
MAX
Test Conditions/Comments
I
I
V
V
V
V
V
V
V
V
V
5.5 V > V
(V
(V
Power Up
Power Down
I
I
Sink Current
Source Current
T
T
Power Down
Power Up
Power Up
Long Period
Short Period
Long Period
Short Period
V
I
I
I
I
I
I
I
I
WDI = 0 V
WDI = V
V
V
I
I
V
V
OUT
OUT
SINK
SINK
SINK
SINK
SOURCE
SINK
SINK
SOURCE
SINK
SOURCE
SINK
SOURCE
CC
BATT
BATT
BATT
BATT
BATT
BATT
CC
CC
IL
CC
CC
IN
IN
A
A
BATT
BATT
= +25 C
= +25 C
unless otherwise noted)
= 0.4, V
= –20 mV
= 20 mV
< (V
= 4.5 V
> (V
= 5 V
= 5 V
= 25 mA
= 250 mA
= 50 A, V
= 3.2 mA
= 25 mA
= 3.2 mA, V
= 3.2 mA
= 3.2 mA, V
= 3.2 mA, V
= 3.2 mA
= 2.8 V, I
= 2.0 V, I
= 4.5 V, I
= 2.8 V
= 2.0 V
= 4.5 V
+0.2 V) < V
+0.2 V) < V
= 1.6 mA, V
= 1 A, V
= 500 A, V
= 1 A
BATT
BATT
OUT
CC
IH
> V
– 1.2 V), V
– 1 V)
= 0.75
CC
OUT
OUT
OUT
BATT
CC
CC
CC
CC
= 1 V, V
CC
CC
= 10 mA
= 5 mA
= 20 mA
CC
= 4.25 V
= 4.25 V
= 5 V
= 4.25 V
CC
+ 0.2 V
, T
V
= 5 V
= 5 V
BATT
CC
A
BATT
= +25 C
REV. 0
= 2.8 V
= 0 V

Related parts for ADM691AR