E3X-NM41 Omron, E3X-NM41 Datasheet - Page 5

QUAD AUTOTUNE PNP RMT TCH

E3X-NM41

Manufacturer Part Number
E3X-NM41
Description
QUAD AUTOTUNE PNP RMT TCH
Manufacturer
Omron
Series
E3X-Nr
Type
Fiber Optic Sensorr
Datasheets

Specifications of E3X-NM41

Output Type
PNP
Amplifier Type
Four Channel
Voltage - Supply
12 V ~ 24 V
Current - Supply
150mA
Mounting Type
DIN Rail
Length/height, External
33mm
Response Time
1ms
Sensor Input
Fiber Optic
External Width
32.2mm
External Depth
59mm
Operating Temperature Min
-25°C
Operating Temperature Max
55°C
Output Current Max
100mA
Rohs Compliant
Yes
Fiber Optic Sensor Type
Fiber Optic Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XNM41

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3X-NM41
Manufacturer:
EVERLIGHT
Quantity:
20 390
E3X-N
J MAXIMUM SENSITIVITY SETTING
Note: The sensitivity of the E3X-NT and E3X-NM are set to maximum before shipping. When resetting the sensitivity of the E3X-NT or
Procedure
1
2
3
4
5
6
E3X-NM to maximum after no-object teaching or with/without-object teaching, follow the steps described below.
Operation
Locate the sensor head within the rated sensing range with the E3X-Nj.
Set the mode selector to TEACH.
The flashing function of the E3X-Nj will be activated. Therefore,
adjust the optical axes so that the tip of the emitting fiber will be lit. If
the optical axes are divergent, the tip of the emitting fiber will flash
and the built-in buzzer of the E3X-Nj will beep.
Press the teaching button for three seconds minimum with or without
a sensing object. In the case of the E3X-NM, select a channel with the
channel selector, at which time the stability indicator for the selected
channel will flash.
The teaching indicator (red) turns green.
The built-in buzzer beeps once when the color of the teaching
indicator is red.
The built-in buzzer beeps continuously when the color of the teaching
indicator is green.
Note: The built-in buzzer will stop beeping when the teaching button
Set the mode selector to RUN to complete the sensitivity setting.
The teaching indicator is OFF.
Note: When the sensitivity is set to maximum, the sensitivity will be
Select the logical output required with the operation mode selector.
is no longer being pressed.
automatically adjusted regardless of the set distances of the
fibers or light.
6
E3X-NT
---
TEACH
TEACH
TEACH
RUN
RUN
L
D
ON
ON
E3X-NM
L ON
D ON
TEACH
TEACH
CH
TIMER
TIMER
RUN
RUN
SET
SET
1
TEACH
2 3 4
E3X-N