XB24-PDK Digi International/Maxstream, XB24-PDK Datasheet - Page 41

no-image

XB24-PDK

Manufacturer Part Number
XB24-PDK
Description
KIT DEV PRO ZIGBEE
Manufacturer
Digi International/Maxstream
Series
XBee™r
Type
802.15.4/Zigbeer
Datasheets

Specifications of XB24-PDK

Frequency
2.4GHz
For Use With/related Products
Xbee-PRO Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
D0 - D4 (DIOn Configuration) Commands
D5 (DIO5 Configuration) Command
D6 (DIO6 Configuration) Command
<I/O Settings> The D0, D1, D2, D3 and D4 com-
mands are used to select/read the behavior of
their respective AD/DIO lines (pins 20, 19, 18, 17
and 11 respectively).
Options include:
<I/O Settings> The D5 command is used to
select/read the behavior of the DIO5 line (pin 15).
Options include:
<I/O Settings> The D6 command is used to
select/read the behavior of the DIO6 line (pin 16).
Options include:
© 2009 Digi Internatonal, Inc.
• Analog-to-digital converter
• Digital input
• Digital output
• Associated Indicator (LED blinks when the
• Analog-to-digital converter
• Digital input
• Digital output
• RTS flow control
• Analog-to-digital converter
• Digital input
• Digital output
module is associated)
AT Commands:
ATD0, ATD1, ATD2, ATD3, ATD4
Parameter Range:0 - 5
Default Parameter Value:0
Minimum Firmware Version Required: 1.x.A0
AT Command: ATD5
Parameter Range:0 - 5
Default Parameter Value:1
Parameters 2-5 supported as of firmware
version 1.xA0
AT Command: ATD6
Parameter Range:0 - 5
Default Parameter Value:0
Parameters 3-5 supported as of firmware
version 1.xA0
Parameter
Parameter
Parameter
0
1
2
3
4
5
0
1
2
3
4
5
0
1
2
3
4
5
Associated Indicator
RTS Flow Control
Configuration
Configuration
Configuration
Disabled
Disabled
Disabled
DO high
DO high
DO high
DO low
DO low
DO low
ADC
ADC
n/a
n/a
DI
DI
DI
     41

Related parts for XB24-PDK