RFHCS362FT-I/SS Microchip Technology, RFHCS362FT-I/SS Datasheet - Page 6

IC CODE HOPPNG ENCDR W/RF 20SSOP

RFHCS362FT-I/SS

Manufacturer Part Number
RFHCS362FT-I/SS
Description
IC CODE HOPPNG ENCDR W/RF 20SSOP
Manufacturer
Microchip Technology
Datasheets

Specifications of RFHCS362FT-I/SS

Frequency
310MHz ~ 440MHz
Applications
Automotive, Building Access, Garage Openers
Modulation Or Protocol
ASK, FSK
Data Rate - Maximum
3.3 kbps
Power - Output
-12dBm ~ 2dBm
Current - Transmitting
11.5mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
2.2 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
20-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Memory Size
-
PIC16F716
3. Module: Interrupts
REGISTER 2-3:
DS80184F-page 6
bit 7
Legend:
R = Readable bit
-n = Value at POR
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Note 1:
The IOCB register is not used on this device. The
interrupt-on-change feature will automatically be
enabled for any RB<7:4> configured as an input.
See Section 3.2 “PORTB and the TRISB Regis-
ter” in the data sheet (DS41206B) for more
information.
R/W-0
GIE
T0IF bit is set when Timer0 rolls over. Timer0 is unchanged on Reset and should be initialized before
clearing T0IF bit.
GIE: Global Interrupt Enable bit
1 = Enables all unmasked interrupts
0 = Disables all interrupts
PEIE: Peripheral Interrupt Enable bit
1 = Enables all unmasked peripheral interrupts
0 = Disables all peripheral interrupts
T0IE: Timer0 Overflow Interrupt Enable bit
1 = Enables the Timer0 interrupt
0 = Disables the Timer0 interrupt
INTE: RB0/INT External Interrupt Enable bit
1 = Enables the RB0/INT external interrupt
0 = Disables the RB0/INT external interrupt
RBIE: PORTB Change Interrupt Enable bit
1 = Enables the PORTB change interrupt
0 = Disables the PORTB change interrupt
T0IF: Timer0 Overflow Interrupt Flag bit
1 = TMR0 register has overflowed (must be cleared in software)
0 = TMR0 register did not overflow
INTF: RB0/INT External Interrupt Flag bit
1 = The RB0/INT external interrupt occurred (must be cleared in software)
0 = The RB0/INT external interrupt did not occur
RBIF: PORTB Change Interrupt Flag bit
1 = When at least one of the PORTB general purpose I/O pins changed state (must be cleared in soft-
0 = None of the PORTB general purpose I/O pins have changed state
R/W-0
PEIE
ware)
INTCON: INTERRUPT CONTROL REGISTER
W = Writable bit
‘1’ = Bit is set
R/W-0
T0IE
R/W-0
INTE
(1)
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
R/W-0
RBIE
T0IF
R/W-0
(1)
 2010 Microchip Technology Inc.
x = Bit is unknown
R/W-0
INTF
R/W-x
RBIF
bit 0