CLRC63201T/0FE,112 NXP Semiconductors, CLRC63201T/0FE,112 Datasheet - Page 11

IC I.CODE HS READER 32-SOIC

CLRC63201T/0FE,112

Manufacturer Part Number
CLRC63201T/0FE,112
Description
IC I.CODE HS READER 32-SOIC
Manufacturer
NXP Semiconductors
Series
I-Coder
Datasheets

Specifications of CLRC63201T/0FE,112

Rf Type
Read Only
Frequency
13.56MHz
Features
ISO14443-A, ISO14443-B, ISO15693, ISO18000-3
Package / Case
32-SOIC (0.300", 7.50mm Width)
Product
RFID Readers
Operating Temperature Range
- 25 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-2199-5
935269690112
CLRC632
CLRC63201TD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CLRC63201T/0FE,112
Manufacturer:
IR
Quantity:
3 400
Part Number:
CLRC63201T/0FE,112
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Philips Semiconductors
Multiple Protocol Contactless Reader IC
4 MIFARE
4.1 CRYPTO I: Card Authentication
For correct authentication of MIFARE Classic
products the fast CRYPTO 1 stream cipher is
available. The corresponding keys have to be
programmed into the secure non-volatile key
memory of the CL RC632.
Only two commands need to be sent by
application software to turn on CRYPTO 1
secured communication.
4.1.1 INITIATING CARD AUTHENTICATION
The correct key for the authentication has to be
selected from the secure internal non-volatile key
memory and loaded into the internal CRYPTO1
register. Next the authentication command is
transmitted to the card.
After receiving the first message token from the
card, the µ-Controller has to check the
®
CLASSIC RELATED ITEMS
11
communication status flags. If communication so
far has been successful the second part of the
authentication procedure can be started.
4.1.2 SECOND PART OF CARD
AUTHENTICATION
Data to be transmitted to the card in this phase
are generated automatically by the internal
CRYPTO 1 unit inside the CL RC632. To request
this action the according command has to be
triggered.
The card will respond with the second message
token. Then the communication status flags have
to be checked by the µ-Controller. If
authentication has been successful further
communication with a MIFARE Classic card
continues CRYPTO 1 enciphered.
Short Form Specification Rev. 3.2 April 2005
CL RC632
PUBLIC

Related parts for CLRC63201T/0FE,112