MPX5050GP Freescale Semiconductor, MPX5050GP Datasheet - Page 6

SENSOR GAUGE PRESS 7.25 PSI MAX

MPX5050GP

Manufacturer Part Number
MPX5050GP
Description
SENSOR GAUGE PRESS 7.25 PSI MAX
Manufacturer
Freescale Semiconductor
Series
MPX5050r
Datasheet

Specifications of MPX5050GP

Pressure Type
Gauge
Operating Pressure
7.25 PSI
Port Size
Male, 0.194" (4.9276mm) Tube
Output
0 ~ 4.7V
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
6-SIP
Accuracy
2.5 %
Mounting Style
Through Hole
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
5 V
Supply Voltage (min)
4.75 V
Supply Voltage (max)
5.25 V
Supply Current
7 mA
Output Voltage
4.7 V
Shutdown
No
Operating Pressure Range
0 To 50kPa
Connection Size
4.928mm
Sensitivity, V/p
90mV/kPa
Sensor Case Style
SIP
No. Of Pins
6
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPX5050GP
Manufacturer:
FREESCALE
Quantity:
20 000
MPX5050
6
as the Pressure (P1) side and the Vacuum (P2) side. The
Pressure (P1) side is the side containing fluorosilicone gel
which protects the die from harsh media. The MPX pressure
MPX5050D
MPX5050DP
MPX5050GP
MPXV5050GP
MPXV5050DP
MPXV5050GC6U/T1
Freescale designates the two sides of the pressure sensor
Pressure
Nominal Transfer Value:
Temperature Error Band
Pressure Error Band
Transfer Function
Temperature
Factor
Error
NOTE: The Temperature Multiplier is a linear response from 0° to –40°C and from 85° to 125°C.
Part Number
–1.0
–2.0
–3.0
3.0
2.0
1.0
0.0
4.0
3.0
2.0
1.0
0.0
PRESSURE (P1)/VACUUM (P2) SIDE IDENTIFICATION TABLE
V
± (Pressure Error x Temp. Factor x 0.018 x V
V
out
S
= 5.0 V ± 0.25 Vdc
= V
S
–40
0
(P x 0.018 + 0.04)
–20
10
Error Limits for Pressure
20
0
30
20
Temperature in °C
Case Type
0 to 85
+125
Temp
–40
867C
867B
482A
1369
1351
867
40
sensor is designed to operate with positive differential
pressure applied, P1 > P2.
table below:
40
The Pressure (P1) side may be identified by using the
S
Multiplier
)
50
60
3
1
3
80
60
Stainless Steel Cap
Side with Part Marking
Side with Port Attached
Side with Port Attached
Side with Part Marking
Vertical Port Attached
100
Pressure (P1) Side Identifier
120
Pressure (in kPa)
0 to 50 (kPa)
140
Pressure
Freescale Semiconductor
Error (Max)
±1.25 (kPa)
Sensors

Related parts for MPX5050GP