MPX5100GP Freescale Semiconductor, MPX5100GP Datasheet - Page 3

SENSOR GAUGE PRESS 14.5 PSI MAX

MPX5100GP

Manufacturer Part Number
MPX5100GP
Description
SENSOR GAUGE PRESS 14.5 PSI MAX
Manufacturer
Freescale Semiconductor
Series
MPX5100r
Datasheet

Specifications of MPX5100GP

Pressure Type
Gauge
Operating Pressure
0 ~ 14.5 PSI
Port Size
Male, 0.194" (4.9276mm) Tube
Output
0.2 ~ 4.7V
Accuracy
±2.5%
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
6-SIP
Mounting Style
Through Hole
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
5 V
Supply Voltage (min)
4.75 V
Supply Voltage (max)
5.25 V
Supply Current
7 mA
Output Voltage
4.7 V
Shutdown
No
Operating Pressure Range
0 To 100kPa
Connection Size
4.928mm
Sensitivity, V/p
45mV/kPa
Sensor Case Style
SIP
No. Of Pins
6
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPX5100GP
Manufacturer:
FREESCALE
Quantity:
20 000
Sensors
Freescale Semiconductor
Operating Characteristics
Table 1. Operating Characteristics
Figure 5
Pressure Range
Supply Voltage
Supply Current
Minimum Pressure Offset
Full Scale Output
Full Scale Span
Accuracy
Sensitivity
Response Time
Output Source Current at Full Scale Output
Warm-Up Time
Offset Stability
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
2. Device is ratiometric within this specified excitation range.
3. Offset (V
4. Full Scale Output (V
5. Full Scale Span (V
6. Accuracy (error budget) consists of the following:
7. Response Time is defined as the time for the incremental changed in the output to go from 10% to 90% of its final value when subjected to
8. Warm-Up Time is defined as the time required for the product to meet the specified output voltage after the Pressure has been stabilized.
9. Offset Stability is the product’s output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
Gauge, Differential: MPX5100D/MPX5100G/MPXV5100G
Absolute: MPX5100A
@ V
@ V
@ V
minimum rated pressure.
• Linearity:
• Temperature Hysteresis:Output deviation at any temperature within the operating temperature range, after the temperature is cycled to
• Pressure Hysteresis:
• TcSpan:
• TcOffset:
• Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of V
a specified step change in pressure.
S
S
S
(6)
required to meet electrical specifications.)
= 5.0 V
= 5.0 V
= 5.0 V
OFF
(9)
(2)
(8)
(5)
(7)
) is defined as the output voltage at the minimum rated pressure.
(1)
(4)
FSS
FSO
(3)
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
) is defined as the output voltage at the maximum or full rated pressure.
Output deviation from a straight line relationship with pressure over the specified pressure range.
and from the minimum or maximum operating temperature points, with zero differential pressure applied.
Output deviation at any pressure within the specified range, when this pressure is cycled to and from minimum
or maximum rated pressure at 25°C.
Output deviation over the temperature range of 0° to 85°C, relative to 25°C.
Output deviation with minimum pressure applied over the temperature range of 0° to 85°C, relative to 25°C.
Characteristic
Differential and Absolute (0 to 85°C)
Differential and Absolute (0 to 85°C)
(
V
S
= 5.0 Vdc, T
A
= 25°C unless otherwise noted, P1 > P2. Decoupling circuit shown in
(0 to 85°C)
Symbol
V
V
V
P
V/P
I
V
FSO
I
OFF
FSS
t
O+
OP
O
R
S
0.088
4.587
4.75
Min
15
0
4.700
4.500
0.20
±0.5
Typ
5.0
7.0
1.0
0.1
45
20
FSS
at 25°C.
Pressure
0.313
4.813
Max
5.25
±2.5
100
115
10
MPX5100
mV/kPa
%V
%V
mAdc
mAdc
Unit
kPa
V
V
V
V
ms
ms
DC
DC
DC
DC
FSS
FSS
3