IS-C0203-F-E NKK Switches, IS-C0203-F-E Datasheet - Page 10

SMARTSWITCH CONTROLLER LCD

IS-C0203-F-E

Manufacturer Part Number
IS-C0203-F-E
Description
SMARTSWITCH CONTROLLER LCD
Manufacturer
NKK Switches
Datasheets

Specifications of IS-C0203-F-E

Accessory Type
Controller
Description/function
SMARTSWITCH Development Kit
For Use With/related Products
SmartSwitch™ Switches
For Use With
360-2345 - SWITCH COMPACT LCD 64X32 RGB360-2343 - SWITCH LCD 64X32 RGB360-2341 - DISPLAY LCD 64X32IS01BCEF - SMARTDISPLAY SUPER YEL/GRN LEDIS01BCE - SMARTDISPLAY SUPER YELLOW LEDIS15SBFP4B - SMARTSWITCH COMPACT WHITE LEDIS15SBCP4EF - SMARTSWITCH COMPACT YEL/GRN LEDIS15SACP4CF - SMARTSWITCH COMPACT RED/GRN LEDIS15ABFP4B - SMARTSWITCH STD BLK W/WHITE LEDIS15ABDP4B - SMARTSWITCH STD BLU W/WHITE LEDIS15ABDP4EG - SMARTSWITCH STD YELLOW/BLUE LEDIS15ABDP4E - SMARTSWITCH STD BLUE W/YEL LEDIS15ABCP4EF - SMARTSWITCH STD YEL/GRN LEDIS15ABCP4E - SMARTSWITCH STD LED YELLOWIS15AACP4CF - SMARTSWITCH STD YEL RED/GRN LED360-2334 - SMARTDISPLAY RED/GREEN/BLUE360-2333 - SMARTDISPLAY SUPER RED/GREEN LED360-2332 - SMARTSWITCH STANDARD RED/GRN/BLU360-2331 - SMARTSWITCH COMPACT RED/GRN/BLU360-2330 - SMARTSWITCH STD RED/GRN LED360-2329 - SMARTSWITCH COMPACT RED/GRN LED
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
360-2425
7850 East Gelding Drive • Scottsdale, AZ 85260-3420
[Address] is one byte with value of 01H to FFH sent as ASCII HEX format.
[Legend Block] is 125 bytes in LCD 36x24 mode and is 256 bytes in LCD 64x32 mode transmitted in ASCII
HEX format.
The controller disables the timers and switch execution upon receiving this command. However, the switches
are still scanned and reported. They are enabled upon reboot/power up or by command from host.
Command to upload a Legend block
[Address] is one byte with value of 01H to FFH sent as ASCII HEX format.
The controller transmits back the image (125 bytes in LCD 36x24 mode and is 256 bytes in LCD 64x32
mode) in HEX format.
The controller disables the timers and switch execution upon receiving this command. However, the switches
are still scanned and reported. They are enabled upon reboot/power up or by command from host.
Command to download attribute block
[Address] is one byte with value of 01H to FFH sent as ASCII HEX format.
[Attribute Block] is six bytes in LCD 36x24 mode and is eight bytes in LCD 64x32 mode transmitted in
ASCII HEX format.
The controller disables the timers and switch execution upon receiving this command. However, the switches
are still scanned and reported. They are enabled upon reboot/power up or by command from host.
Command to upload an attribute block
[Address] is one byte with value of 01H to FFH sent as ASCII HEX format.
[Attribute Block] is six bytes in LCD 36x24 mode and is eight bytes in LCD 64x32 mode transmitted in
ASCII HEX format.
The controller transmits back the [Attribute block] in hex format.
IS-Dev Kit-5 and IS-Dev Kit-6 Users Manual A.doc
This command uploads a Legend block from the EEPROM location to the host.
This command downloads an attribute block from the host to the EEPROM location.
This command uploads an attribute block from the EEPROM location to the host.
command format:
transmit format:
command format: 2AH [Address] [Attribute Block]
transmit format:
command format: 2BH [Address]
transmit format:
Toll Free 1.877.2BUYNKK (877.228.9655) • Phone 480.991.0942 • Fax 480.998.1435
(xxH)
(xxH)
(xxH)
29H
IS-Dev Kit-5 and IS-Dev Kit-6 Users
www.nkkswitches.com • Email engineering@nkkswitches.com
[Address]
(xxAH)
(xxAH)
(xxAH)
Manual
(xxAH)
Page 10 of 24
1209