G3NA-240B-AC100-120 Omron, G3NA-240B-AC100-120 Datasheet
G3NA-240B-AC100-120
Specifications of G3NA-240B-AC100-120
Related parts for G3NA-240B-AC100-120
G3NA-240B-AC100-120 Summary of contents
Page 1
... Photocoupler p Phototriac Photocoupler p *Loss time increases under 75 VAC. (Refer to page 163.) Note: When ordering a TÜV-approved model, add “-UTU” to the model number as shown below: Example: G3NA-210B-UTU 156 Indicator Rated output load (Applicable output load 240 VAC* Yes (19 t 264 VAC) ...
Page 2
... Note: The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC, the input impedance is measured at 120 VAC). *With constant current input circuit system. The impedance for the G3NA-jjjB-UTU max. **Refer to the Engineering Data for further details. ...
Page 3
... Malfunction Hz, 1.5-mm double amplitude Shock resistance Malfunction: 1,000 m/s Ambient temperature Operating: – (with no icing or condensation) Storage: Approved standards UL508 File No. E64562/CSA C22.2 (No.0, No.14) File No. LR35535 (except for G3NA-450B) TÜV R9151660 (EN60950) (except for G3NA-4j0B) Ambient humidity Operating: 45% to 85% Weight Approx 158 G3NA-240B 1 ...
Page 4
... Y92B-N150) 20 With iron plate measuring 100 x 100 x 0 Without heat sink Ambient temperature ( C) G3NA G3NA-220B/420B With standard heat sink (Y92B-A100 or Y92B-N100) or alumi- num plate measuring 200 mm x 200 With iron plate measuring 100 x 100 x 0 Without heat sink Ambient temperature ( C) ...
Page 5
... SSR the graph shows that the heat sink 2 size is about 450 cm . Therefore, if the heat sink is square, one side of the heat sink must (15 G3NA G3NA-220B/420B Energizing time (ms) Temperature Characteristics (with Must Operate Voltage and Must Release Voltage) G3NA-2jjB AC Input Ambient temperature ( 450) or longer. ...
Page 6
... In the case of surface mounting, a 30% derating of the load current is required. The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mount- ing hole dimensions. G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B 58 max. 47.5 44 G3NA-240B, G3NA-440B, G3NA-450B 58 min ...
Page 7
... Y92B-A250 Three, M4 holes 47.6 R2.2 50 0.1 56 0.5 150 max. Four, M4 190.5 max. 130.5 max. 70 max. G3NA Mounting Holes 35 0.2 75 max. Two, 4.4-dia holes 90 0.4 13 4.5 Weight: approx. 400 g Mounting Holes 35 0.2 Two, 4.4-dia. 104 max holes 90 0 ...
Page 8
... Load Connection For an AC load, use a power supply rated Hz. The maximum operating frequency is 10 Hz. The G3NA has a built-in varistor for overvoltage protection. Zero Cross Function An SSR with a zero cross function operates when an AC load volt- age reaches the zero point or its vicinity. This reduces clicking ...
Page 9
... G3NA When attaching a heat sink to the G3NA, apply Silicone Grease or equivalent heat conductive grease on the heat sink. (Toshiba Sili- con, Shinetsu Silicon, etc.) Tighten the mounting screws of the heat sink with a torque of 0. EN55011 Measurement of Mains Terminal Disturbance Voltage The G3NA-UTU conforms to EN55011 standards when a capacitor is connected to the load power supply as shown in the following cir- cuit diagram ...