K3012P Vishay, K3012P Datasheet - Page 2

Triac & SCR Output Optocouplers Phototriac Output

K3012P

Manufacturer Part Number
K3012P
Description
Triac & SCR Output Optocouplers Phototriac Output
Manufacturer
Vishay
Datasheets

Specifications of K3012P

Isolation Voltage
3750 Vrms
Configuration
1
Maximum Continuous Output Current
100 mA
Maximum Input Current
80 mA
Maximum Operating Temperature
+ 85 C
Maximum Power Dissipation
350 mW
Maximum Reverse Diode Voltage
5 V
Minimum Operating Temperature
- 40 C
Mounting Style
Through Hole
Output Type
AC
Package / Case
DIL
Typical Input Voltage
1.25 V
Zero-crossing Circuit
No
Output Device
Triac
Peak Output Voltage (vdrm)
250 V
Maximum Input Voltage
1.6 V
Maximum Output Voltage
175 VAC
Minimum Trigger Current
2 mA (Typ)
No. Of Channels
1
Optocoupler Output Type
Phototriac
Input Current
50mA
Output Voltage
250V
Opto Case Style
DIP
No. Of Pins
6
Mounting Type
Through Hole
Approval Bodies
UL, VDE
Blocking Voltage
250V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
K3012P
Quantity:
70 000
Company:
Part Number:
K3012P-X007T
Quantity:
70 000
K3010P, K3010PG Series
Vishay Semiconductors
Notes
(1)
Notes
(1)
(2)
(3)
www.vishay.com
520
ABSOLUTE MAXIMUM RATINGS
PARAMETER
INPUT
Reverse voltage
Forward current
Forward surge current
Power dissipation
Junction temperature
OUTPUT
Off state output terminal voltage
On state RMS current
Peak surge current, non-repetitive
Power dissipation
Junction temperature
COUPLER
Isolation test voltage (RMS)
Total power dissipation
Ambient temperature range
Storage temperature range
Soldering temperature
ELECTRICAL CHARACTERISTICS
PARAMETER
INPUT
Forward voltage
Junction capacitance
OUTPUT
Forward peak off-state voltage
(repetitive)
Peak on-state voltage
Critical rate of rise of off-state voltage
COUPLER
Collector emitter saturation voltage
Holding current
T
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not
implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute maximum
ratings for extended periods of the time can adversely affect reliability.
T
Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the result of engineering
evaluation. Typical values are for information only and are not part of the testing requirements.
Test voltage must be applied within dV/dt ratings.
I
FT
amb
amb
is defined as a minimum trigger current.
= 25 °C, unless otherwise specified.
= 25 °C, unless otherwise specified.
(3)
For technical questions, contact: optocoupler.answers@vishay.com
V
I
I
TEST CONDITION
F
FT
2 mm from case, t ≤ 10 s
S
V
= 10 mA, V
R
= 3 V, R
I
I
= 0, I
RDM
TEST CONDITION
TM
I
= 0, f = 1 MHz
F
(1)
= 50 mA
= 100 mA
Optocoupler, Phototriac
(1)
= 100 nA
t
t
FT
p
P
t = 1 min
≤ 10 ms
Output, 250 V V
≤ 10 µs
= 30 mA,
L
= 150 Ω
S
≥ 3 V
K3010PG
K3011PG
K3012PG
K3010P
K3011P
K3012P
PART
DRM
SYMBOL
V
T
P
I
P
V
I
I
T
P
T
FSM
TRM
TMS
V
DRM
I
T
T
amb
diss
diss
ISO
stg
sld
F
tot
R
j
j
SYMBOL
V
dV/d
dV/d
DRM
V
V
I
I
I
I
I
I
C
I
FT
FT
FT
FT
FT
FT
TM
H
F
j
tcrq
tcr
(2)
- 55 to + 100
- 40 to + 85
MIN.
250
0.1
VALUE
3750
100
100
250
100
300
100
350
260
1.5
80
5
3
TYP.
1.25
100
1.5
0.2
50
10
8
8
5
5
2
2
Document Number: 83504
Rev. 1.9, 10-Dec-08
MAX.
1.6
15
15
10
10
3
5
5
UNIT
V
mW
mW
mW
mA
mA
°C
°C
°C
°C
°C
RMS
V
A
V
A
UNIT
mA
mA
mA
mA
mA
mA
pF
nA
nA
µA
V
V
V

Related parts for K3012P