JD2D3-CDS-6F Digi International, JD2D3-CDS-6F Datasheet - Page 25

no-image

JD2D3-CDS-6F

Manufacturer Part Number
JD2D3-CDS-6F
Description
Interface Modules & Development Tools RS-232 Cable 6 ft. Sub straight through
Manufacturer
Digi International
Datasheet

Specifications of JD2D3-CDS-6F

Interface Type
RS-232
Product
Interface Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 4‐03. XTend Commands (The RF modems expect numerical values in hexadecimal. Hexadecimal values are designated by a “0x” 
9XTend™ RS‐232/485 RF Modem ‐ Product Manual v2.x4x [2007.01.04]
AT
Command
%V
AM
AP v2.x20*
AT
BD
BR
BT
CC
CD
CF
CN
CS
CT
DB
DT
E0
E1
ER
FH
FL
FS
FT
GD
HP
HT
HV
ID
KY
LH
MD v2.x20*
MK
MT
MY
NB
PB v2.x20*
PD v2.x20*
4.3. Command Reference Table
prefix. Decimal equivalents are designated by a “d” suffix.)
Binary
Command
0x3B (59d)
0x40 (64d)
--
0x05 (5d)
0x15 (21d)
0x39 (57d)
0x04 (4d)
0x13 (19d)
0x28 (40d)
--
0x09 (9d)
0x1F (31d)
0x06 (6d)
0x36 (54d)
0x00 (0d)
0x0A (10d)
0x0B (11d)
0x0F (15d)
0x0D (13d)
0x07 (7d)
0x3E (62d)
0x24 (36d)
0x10 (16d)
0x11 (17d)
0x03 (3d)
--
0x27 (39d)
0x3C (60d)
0x0C (12d)
0x31 (49d)
0x12 (18d)
0x3D (61d)
0x2A (42d)
0x23 (35d)
0x45 (69d)
0x47 (71d)
AT Command Name
Board Voltage
Auto-set MY
API Enable
Guard Time After
Interface Data Rate
RF Data Rate
Guard Time Before
Command Sequence Character
GPO2 Configuration
Number Base
Exit Command Mode
GPO1 Configuration
Command Mode Timeout
Received Signal Strength
Destination Address
Echo Off
Echo On
Receive Error Count
Force Wake-up Initializer
Software Flow Control
Forced Sync Time
Flow Control Threshold
Receive Good Count
Hopping Channel
Time before Wake-up Initializer
Hardware Version
Modem VID
AES Encryption Key
Wake-up Initializer Timer
RF Mode
Address Mask
Multi-Transmit
Source Address
Parity
Polling Begin Address
Minimum Polling Delay
© 2007 MaxStream, Inc.
Parameter Range
0x2CCCA - 0x5BFFA [read-only]
--
0 - 2
2 - (ATST-3) [x 100 msec]
0 - 8 (standard rates)
0x39 - 0x1C9C38 (non-standard rates)
0 - 1
0 - 0xFFFF [x 100 msec]
0x20 - 0x7F
0 - 4
0 - 2
--
0 - 4
2 - 0xFFFF [x 100 ms]
0x6E - 0x28 [read-only]
0 - 0xFFFF
--
--
0 - 0xFFFF
--
0 - 1
0 - 0xFFFF [x 10 msec]
0 - (DI buffer size - 0x11) [Bytes]
0 - 0xFFFF
0 - 9
0 - 0xFFFF [x 100 msec]
0 - 0xFFFF [read-only]
0x11 - 0x7FFF (user-settable)
0x8000 - 0xFFFF (factory-set, read-only)
0 - (Any other 64-digit hex valid key)
0 - 0xFF [x 100 msec]
0 - 6
0 - 0xFFFF
0 - 0xFF
0 - 0xFFFF
0 - 4
0 - 0xFFFF
0 - 0xFFFF
(Base: (x 1 ms), Remote: [x 10 ms])
Command
Category
Diagnostics
Networking & Security
Serial Interfacing
Command Mode Options 2
Serial Interfacing
RF Interfacing
Command Mode Options 2
Command Mode Options 1
Serial Interfacing
Command Mode Options 1
Command Mode Options --
Serial Interfacing
Command Mode Options 2
Diagnostics
Networking & Security
Command Mode Options --
Command Mode Options --
Diagnostics
Sleep (Low Power)
Serial Interfacing
RF Interfacing
Serial Interfacing
Diagnostics
Networking & Security
Sleep (Low Power)
Diagnostics
Networking & Security
Networking & Security
Sleep (Low Power)
Networking & Security
Networking & Security
Networking & Security
Networking & Security
Serial Interfacing
Networking & Security
Networking & Security
Chapter 4 ‐ RF Modem Configuration
# Bytes
Returned
4
--
1
4
1
1
1
2
2
2
--
1
2
2
2
1
2
2
2
2
1
1
2
1
2
1
2
2
Factory
Default
--
--
0
0x0A (10d)
3
1
0x0A (10d)
0x2B ["+"] (43d)
2
1
--
0
0xC8 (200d)
--
0
--
--
0
--
0
0
DI buffer size
minus 0x11
0
0
0xFFFF
(65535d)
--
0x3332
(13106d)
0
1
0
0xFFFF
(65535d)
0
0xFFFF
(65535d)
0
0
0
     25