XR16L580IL-F Exar Corporation, XR16L580IL-F Datasheet - Page 31

UART Interface IC UART

XR16L580IL-F

Manufacturer Part Number
XR16L580IL-F
Description
UART Interface IC UART
Manufacturer
Exar Corporation
Datasheet

Specifications of XR16L580IL-F

Data Rate
1 Mbps
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.25 V
Supply Current
3 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
QFN
No. Of Channels
1
Uart Features
Selectable RX And TX FIFO Trigger Levels, Automatic Software Flow Control, Complete Modem Interface
Supply Voltage Range
2.25V To 5.5V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR16L580IL-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
XR16L580IL-F
Quantity:
15 000
Company:
Part Number:
XR16L580IL-F
Quantity:
15 000
Company:
Part Number:
XR16L580IL-F
Quantity:
15 000
Company:
Part Number:
XR16L580IL-F
Quantity:
15 000
Part Number:
XR16L580IL-FN
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
REV. 1.4.1
MCR[4]: Internal Loopback Enable
MCR[5]: Xon-Any Enable
MCR[6]: Infrared Encoder/Decoder Enable
MCR[7]: BRG Clock Prescaler Select
This register provides the status of data transfers between the UART and the host.
LSR[0]: Receive Data Ready Indicator
LSR[1]: Receiver Overrun Flag
LSR[2]: Receive Data Parity Error Flag
LSR[3]: Receive Data Framing Error Flag
4.9
Logic 0 = Disable loopback mode (default).
Logic 1 = Enable local loopback mode, see loopback section and
Logic 0 = Disable Xon-Any function (for 16C550 compatibility, default).
Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation.
The RX character will be loaded into the RX FIFO, unless the RX character is an Xon or Xoff character and
the L580 is programmed to use the Xon/Xoff flow control.
Logic 0 = Enable the standard modem receive and transmit input/output interface (default).
Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the
infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface
requirement. While in this mode, the infrared TX output will be a logic 0 during idle data conditions.
Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable
Baud Rate Generator without further modification, i.e., divide by one (default).
Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and
feeds it to the Programmable Baud Rate Generator, hence, data rates get reduced 4 times.
Logic 0 = No data in receive holding register or FIFO (default).
Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
Logic 0 = No overrun error (default).
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register
is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into
the FIFO, therefore the data in the FIFO is not corrupted by the error.
Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
Logic 0 = No framing error (default).
Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
Line Status Register (LSR) - Read Only
SMALLEST 2.25V TO 5.5V UART WITH 16-BYTE FIFO AND POWERSAVE
31
Figure 14
.
XR16L580

Related parts for XR16L580IL-F