General Purpose / Industrial Relays REL-MR- 12DC/21 REPLACEMENT RELAY

2961150

Manufacturer Part Number
2961150
Description
General Purpose / Industrial Relays REL-MR- 12DC/21 REPLACEMENT RELAY
Manufacturer
Phoenix Contact
Series
296r
Datasheets

Specifications of 2961150

Coil Voltage
12 V
Contact Rating
14 mA
Contact Termination
Screw
Contact Material
Silver
Coil Resistance
848 Ohms
Contact Form
SPDT
Current, Rating
6 A
Function
Power
Mounting Type
PCB
Phoenix Part Number
REL-MR- 12DC/21
Relay Type
Electro Mechanical
Standards
cULus, CSA, RoHS
Termination
Plug-In
Voltage, Control
12 VAC/VDC
Voltage, Rating
250 VAC/VDC
Contact Rating (current)
6A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Non Latching
Coil Current
14mA
Turn On Voltage (max)
-
Turn Off Voltage (min)
-
Features
-
Termination Style
PC Pin
Operate Time
5ms
Release Time
2.5ms
Coil Power
-
Operating Temperature
-40°C ~ 85°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
REL-MR- 12DC/21
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2961150
PHOENIX CONTACT UAB
http://www.phoenixcontact.lt
Contact side
Contact type
Contact material
Maximum switching voltage
Minimum switching voltage
Maximum inrush current
Min. switching current
Limiting continuous current
Interrupting rating (ohmic load) max.
General data
Length
Height
Width
Test voltage relay winding/relay contact
Ambient temperature (operation)
Ambient temperature (storage/transport)
Operating mode
Service life mechanical
Standards/regulations
Pollution degree
Surge voltage category
Mounting position
Assembly instructions
Order No.: 2961150
Single contact, 1-PDT
AgSnO
250 V AC/DC
12 V AC/DC
(on request)
10 mA
6 A
140 W (for 24 V DC)
20 W (for 48 V DC)
18 W (for 60 V DC)
23 W (for 110 V DC)
40 W (for 220 V DC)
1500 VA (for 250 V AC)
28 mm
15 mm
5 mm
4 kV AC (50 Hz, 1 min)
-40 °C ... 85 °C
-40 °C ... 85 °C
100% operating factor
2 x 10
IEC 60664
IEC 60664 A
DIN VDE 0110
DIN VDE 0106-101
DIN EN 50178/DIN VDE 0160 (in relevant parts)
IEC 60255/DIN VDE 0435 (in relevant parts)
EN 60730/DIN VDE 0631
3
III
Any
In rows with zero spacing
7
cycles
Apr 23, 2009