Specifications of G9EA-1-B-DC24

Contact Form
SPST - NO
Coil Voltage
24 VDC
Contact Rating
60 A
Coil Termination
Screw Terminals
Contact Termination
Screw
Power Consumption
5 W
Coil Current
208 mA
Coil Resistance
115.2 Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
24DC G9EA-1-B
DC Power Relays
G9EA/G9EB/G9EC
DC Control in a Relay
A Leader in Clean Energy with Compact,
Quiet, Energy-efficient Designs
G9EB
G9EA
G9EC

G9EA-1-B-DC24 Summary of contents

Page 1

... DC Power Relays G9EA/G9EB/G9EC DC Control in a Relay A Leader in Clean Energy with Compact, Quiet, Energy-efficient Designs G9EB G9EA G9EC ...

Page 2

... OMRON has improved on the standard DC circuit that switches using a contactor or circuit-breaker by developing the G9EA/G9EB/G9EC DC Power Relay Series. These Relays enable switching high-voltage and high-capacity loads. The switch's gas-filled construction allows a considerable reduction in the relay switch size, while also lowering the operating noise during load switching ...

Page 3

... A at 400 VDC (100 times min.) − 200 VDC Reverse polarity inter- ruption (1,000 times min.) Coil Rated voltage 12, 24, 48, 60, and 100 VDC Power consumption Approx 5.4 W Mechanical endurance 200,000 operations min. G9EA G9EA-1(-B) G9EA-1(-B)-CA High-current conduction conduction 67 ...

Page 4

... Approx. 310 g Refer to page 5 Note: 1. The insulation resistance was measured with a 500-VDC megohmmeter. 2. The impulse withstand voltage was measured with a JEC-212 (1981) standard impulse voltage waveform (1.2 × 50 µ s). Selection Guide 4 DC Power Relays G9EA G9EA-1(-B) G9EA-1(-B)-CA High-current conduction conduction ) 67 ...

Page 5

... Two M3.5 screws are provided for the coil terminal connection. Terminals Contact form Contact terminals Screw terminals SPST-NO (See note 1.) DC Power Relays (60-A, 100-A Models) Rated coil voltage Model 12 VDC G9EA-1-B 24 VDC G9EA-1 48 VDC G9EA-1-B-CA 60 VDC 100 VDC G9EA-1-CA G9EA-1 5 ...

Page 6

... Approx age (at 23°C within 10 minutes) Approx. 5.2 W Approx. 5.4 W G9EA-1(-B)- Ω max. (0.3 m Ω typical) 0.1 V max. (for a carry current of 100 A) 400 VDC 1,000 ops. min. 120 VDC 2,500 ops. min. --- 150 A (10 min) --- 100 A at 120 VDC (150 times min ...

Page 7

... Engineering Data ■ G9EA-1(-B) Switching/Current Conduction Models Maximum Switching Capacity 1,000 500 300 G9EA-1 DC resistive load 100 100 300 500 1,000 Switching voltage (V) Carry Current vs Energizing Time 100,000 10,000 1,000 100 100 300 500 1,000 Carry current (A) ■ G9EA-1(-B)-CA High-current Conduction Models ...

Page 8

... All G9EA-1 Models Must-operate Voltage and Must-release Voltage Distributions 30 Must-operate voltage Sample: G9EA-1 Number: 35 Must-release voltage 100 Percentage of rated voltage (%) Vibration Resistance 10.0 Sample: G9EA-1 Number: 5 8.0 6.0 4.0 2.0 Must-release voltage 0.0 Must-operate voltage −2.0 −4.0 −6.0 −8.0 −10.0 ...

Page 9

... Terminal Arrangement/ Internal Connections (TOP VIEW) 1 (+) (−) 7 Note: Be sure to connect terminals with the correct polarity. Coils do not have polarity. Mounting Hole Dimensions (TOP VIEW) Two 6.5-dia. holes 67.2 60.7 (Terminal height) 10.5 24± 0.1 G9EA-1 8 61± 0.1 8 61± 0.1 9 ...

Page 10

... Dimensions of cutouts for wiring. Two, M5 61± 88 0.1 24± 0 G9EA-1 Note: Be sure to remove the cutouts for wiring that are located in 36 the wiring outlet direction be- fore installing the Terminal Cover. Dimension (mm) Tolerance (mm) ±0 lower ±0 ± higher Dimension (mm) Tolerance (mm) ± ...

Page 11

DC Power Relays (200-A Models) G9EC-1 DC Power Relays Capable of Interrupting High-voltage, High-current Loads • A compact relay ( 86 H)) capable of switching 400-V 200-A DC loads. (Capable of interrupting ...

Page 12

Specifications ■ Ratings Coil Rated voltage Rated current Coil resistance 12.8 Ω 12 VDC 938 mA 51.2 Ω 24 VDC 469 mA 204.8 Ω 48 VDC 234 mA 320.0 Ω 60 VDC 188 mA 888.9 Ω 100 VDC 113 mA ...

Page 13

Engineering Data ■ G9EC-1(-B) Switching/Current Conduction Models Maximum Switching Capacity 1,000 500 300 100 DC resistive load 0.5 0.3 0 100 300 500 1,000 Switching voltage (V) Carry Current vs Energizing ...

Page 14

Vibration Malfunction 1 Sample: G9EC-1 0.9 Number: 5 Unconfirmed area 0.8 0.7 0.6 0.5 Confirmed area 0.4 0.3 0.2 0 100 Frequency (Hz) Shock Malfunction 2 Unit: m Sample: G9EC-1 ...

Page 15

Dimensions Note: All units are in millimeters unless otherwise indicated. Models with Screw Terminals G9EC-1 ...

Page 16

Options Terminal Cover P9EC Power Relays (200-A Models) 44 Dimensions of cutout for wiring G9EC-1 Note: Be sure to remove the cutouts for wiring that are located ...

Page 17

DC Power Relays (25-A Models) G9EB-1 DC Power Relays Capable of Interrupting High-voltage, High-current DC Load • Utilizes a unique gas-filled, fully sealed, non-ceramic construc- tion achieved by using resin with a metal case. This reduces the need for special ...

Page 18

Specifications ■ Ratings Coil Rated voltage Rated current Coil resistance 72 Ω 12 VDC 166.7 mA 288 Ω 24 VDC 83.3 mA 1,152 Ω 48 VDC 41.7 mA 1,800 Ω 60 VDC 33.3 mA 5,000 Ω 100 VDC 20 mA ...

Page 19

Engineering Data ■ G9EB-1-B Switching/Current Conduction Models Maximum Switching Capacity 100 50 DC resistive load 100 300 500 1,000 Switching voltage (V) Carry Current vs Energizing Time 100,000 50,000 30,000 10,000 5,000 ...

Page 20

Vibration Malfunction 1 Sample: G9EB-1-B 12 VDC Number: 5 0.9 Unconfirmed area 0.8 0.7 0.6 0.5 Confirmed area 0.4 0.3 0.2 0 100 Frequency (Hz) Shock Malfunction Z' 2 Unit: m ...

Page 21

Dimensions Note: All units are in millimeters unless otherwise indicated. Screw Terminal Type G9EB-1-B (Mounting hole dimensions) Dimension (mm) Tolerance (mm) ±0 lower ±0 ± higher (Mounting hole dimensions) Two, ...

Page 22

... M5 screws: 1.57 to 2.35 N·m • M4 screws: 0.98 to 1.37 N·m • M3.5 screws: 0.75 to 1.18 N·m 2. The G9EA and G9EC Relays’ contacts have polarity. Be sure to perform connections with the correct polarity. If the contacts are connected with the reverse polarity, the switching characteristics specified in this document cannot be assured ...

Page 23

Common Precautions DC Power Relay 23 ...

Page 24

... To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J144-E1-03 In the interest of product improvement, specifications are subject to change without notice. OMRON RELAY & DEVICES Corporation DC Power Business Promotion Department 1110, Sugi, Yamaga-city, Kumamoto-Pref., 861-0596 Japan Tel: (81)968-44-4641/Fax: (81)968-44-4107 Printed in Japan 0606-0 ...