General Purpose / Industrial Relays 3A SPST-NO 5VDC

G5NB-1A-DC5

Manufacturer Part Number
G5NB-1A-DC5
Description
General Purpose / Industrial Relays 3A SPST-NO 5VDC
Manufacturer
Omron
Series
G5NBr
Datasheets

Specifications of G5NB-1A-DC5

Contact Form
SPST - NO
Coil Voltage
5 VDC
Contact Rating
3 A at 125 VAC
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
200 mW
Contact Material
Silver Alloy
Coil Current
40 mA
Coil Resistance
125 Ohms
Coil Type
Non-Latching
Current, Rating
3 A
Diameter, Mounting
1.1 mm +⁄- 0.1 mm
Dielectric Rating
4000 VAC @ 50⁄60 Hz for 1 Minute Between Coil and Contacts, 750 VAC @ 50⁄60 Hz for 1 Minute Between Contacts of Same Polarity
Dimensions
20.5 mm (Max.) L x 7.2 mm (Max.) W x 15.3 mm (Max.) H
Function
General Purpose
Mounting Type
PCB
Number Of Pins
4
Power, Rating
90 W
Relay Type
Electro Mechanical
Standards
UL, CSA, VDE, RoHS
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-40 °C
Voltage, Control
5 VDC
Voltage, Rating
380 VAC
Operating Temperature
–40°C to 70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G5NB1ADC5BYOMZ

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5NB-1A-DC5V
Manufacturer:
OMRON
Quantity:
12 000
Specifications
■ Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■ Contact Ratings
■ Characteristics
Note: 1. The data shown above are initial value.
2
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated load (resistive, p.f.= 1)
Max. switching voltage
Rated carry current
Max. switching current
Max. switching power
Contact resistance (see note 2)
Operate time
Release time
Insulation resistance (see note 3)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Life expectancy
Minimum permissible load
(reference value) (see note 4)
Ambient temperature
Ambient humidity
Weight
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
2. Measurement conditions: 5 VDC, 1 A, voltage drop method
3. Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter.
4. This value is for a switching frequency of 120 operations/minute. (P level: λ
PCB Relay
Load
G5NB
5 VDC
40.0 mA
125 Ω
75% of rated voltage (max.)
10% of rated voltage (min.)
Standard: 180% of rated voltage (at 23°C)
High-capacity: 170% of rated voltage (at 23°C)
Approx. 200 mW
3 A at 125 VAC
3 A at 30 VDC
250 VAC, 30 VDC
3 A
3 A
375 VA, 90 W
100 mΩ max.
10 ms max.
10 ms max.
1,000 MΩ min. (at 500 VDC)
4,000 VAC, 50/60 Hz for 1 min. between coil and contacts
750 VAC, 50/60 Hz for 1 min. between contacts of same polarity
10,000 V (1.2 x 50 μs) between coil and contacts
Destruction:
Malfunction:
Destruction:
Malfunction:
Mechanical:
Electrical:
Operating: –40°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 4 g
5 VDC, 10 mA
All electrical load ratings are resistive, with operation frequency = 1,800 operations/hour.
12 VDC
16.7 mA
720 Ω
Standard
10 to 55 Hz, 1.5-mm double amplitude
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s
100 m/s
5,000,000 operations min. (18,000 operations/hour)
200,000 operations minimum:
High-capacity
5 A at 125 VAC
3 A at 30 VDC
100,000 operations minimum:
High-capacity
5 A at 250 VAC
2
60
(approx. 10 G)
2
= 0.1 x 10
(approx. 100 G)
18 VDC
11.1 mA
1,620 Ω
-6
operations)
5 A at 250 VAC
3 A at 30 VDC
250 VAC, 30 VDC
5A
5A (AC load,) 3A (DC load)
1,250 VA, 90 W
Standard
3 A at 125 VAC
3 A at 30 VDC
High-capacity
24 VDC
8.3 mA
2,880 Ω