G6D-1A-ASI-DC5 Omron, G6D-1A-ASI-DC5 Datasheet - Page 2

General Purpose / Industrial Relays 5A SPST-NO 5VDC

G6D-1A-ASI-DC5

Manufacturer Part Number
G6D-1A-ASI-DC5
Description
General Purpose / Industrial Relays 5A SPST-NO 5VDC
Manufacturer
Omron
Series
G6D-ASIr
Datasheets

Specifications of G6D-1A-ASI-DC5

Coil Resistance
125 Ohms
Contact Form
SPST - NO
Coil Voltage
5 VDC
Contact Rating
5 A at 250 VAC / 30 VDC
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
200 mW
Contact Material
Silver Alloy
Coil Current
40 mA
Coil Type
Non-Latching
Relay Type
Miniature
Coil Voltage Vdc Nom
5V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
SPST-NO
Current, Rating
5 A
Function
Power
Mounting Type
PCB
Power, Rating
200 mW
Standards
UL, CSA, RoHS
Termination
Solder
Voltage, Control
5 VDC
Voltage, Rating
380 VAC
Long Service Life
Up to 300,000 Operations with a 2 A, 250 VAC/30 VDC Load
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G6D1AASI5DC OMRG6D1AASI5DC

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
G6D-1A-ASI-DC5
Quantity:
5 655
Part Number:
G6D-1A-ASI-DC5V
Manufacturer:
OMRON
Quantity:
12 000
■ Coil Data
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
■ Characteristics
Note: Data shown are of initial value.
■ Characteristic Data
128
5
12
24
Contact resistance
Operate time
Release time
Operating
frequency
Insulation resistance
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Life expectancy
Weight
Maximum Switching Capacity
0.5
0.3
0.1
50
30
10
5
3
1
voltage
0
2. Operating characteristics are measured at a coil temperature of 23°C (73°F).
3. The pick-up voltage is 75% or less of rated voltage if the relay is mounted upside down.
Rated
(VDC)
3
DC resistive
load
DC inductive
load
5
Power PCB Relay
Switching voltage (V)
10
40
16.7
8.3
30
AC inductive
load
cosφ=0.4
current
AC resistive load
100
Rated
(mA)
Mechanical
Electrical
Mechanical durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
Malfunction durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
Mechanical durability 1,000 m/s
Malfunction durability 100 m/s
Operating
Mechanical
Electrical
250 500 1,000
G6D-ASI
125
720
2,880
resistance
Coil
(Ω)
Life Expectancy
100 mΩ max.
10 ms max.
5 ms max.
18,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min. (at 500 VDC)
3,000 VAC, 50/60 Hz for 1 minute between coil and contacts
750 VAC, 50/60 Hz for 1 minute between contacts of the same polarity
6,000 V, 1.20 x 50 μs between coil and contacts
-25° to 70°C (-13° to 158°F)
5% to 85% RH
20 million operations min. (at operating frequency of 18,000 operations/hour)
70,000 operations min. at rated loads (300,000 operations min for 2A at 250 VAC, 30 VDC,
resistive load)
Approx. 3 g (0.10 oz)
500
300
100
30
50
10
3
5
0
250-VAC/30 VDC inductive load
(cosφ=0.4/ L/R=7 ms)
1
2
70% max.
(approx. 10 G)
2
2
(approx. 100 G)
Switching current (A)
250-VAC/30-VDC resistive load
3
Pick-up
voltage
4
5
6
7
% of rated voltage
10% min.
8
9
Dropout
voltage
10
Ambient Temperature vs.
Maximum Coil Voltage
Note: The maximum coil voltage is the
200
180
160
140
120
100
80
60
0
160% at 23°C
maximum voltage that can be
applied to the relay coil.
23 30
Maximum
voltage
Ambient temperature (°C)
40
50
60
Approx. 200
consumption
70
Power
80
(mW)
90