G6B-2114P-US-DC12 Omron, G6B-2114P-US-DC12 Datasheet - Page 4

General Purpose / Industrial Relays SPST-NO + -NC 12VDC

G6B-2114P-US-DC12

Manufacturer Part Number
G6B-2114P-US-DC12
Description
General Purpose / Industrial Relays SPST-NO + -NC 12VDC
Manufacturer
Omron
Series
G6Br

Specifications of G6B-2114P-US-DC12

Coil Resistance
480 Ohms
Contact Form
SPST - NO / SPST - NC
Coil Voltage
12 VDC
Contact Rating
5 A at 250 VAC
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
200 mW
Contact Material
Silver Alloy
Coil Current
16.7 mA
Coil Type
Non-Latching
Relay Type
General Purpose
Coil Voltage Vdc Nom
12V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Current, Rating
5 A
Diameter, Mounting
0.04 in.
Dimensions
0.39 in. W (Max.) x 0.39 in. H (Max.)
Function
Power
Material, Contact
Ag-Alloy
Mounting Type
PCB
Number Of Pins
4
Power, Rating
1250⁄150 VA⁄W
Standards
UL, CSA, FCC
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-25 °C
Termination
Through Hole
Voltage, Control
12 VDC
Voltage, Rating
380 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6B-2114P-US-DC12V
Manufacturer:
OMRON
Quantity:
12 000
Company:
Part Number:
G6B-2114P-US-DC12V
Quantity:
5 655
■ Approved Standards
UL Recognized (File No. E41643) / CSA Certified (File No. LR31928)
Engineering Data
152
G6B-1114P-US
G6B-1114C-US
G6BU-1114P-US
G6BU-1114C-US
G6BK-1114C-US
G6BK-1114C-US
G6B-1174P-US
G6B-1174C-US
G6B-2114P-US
G6B-2114C-US
G6B-2214P-US
G6B-2214C-US
G6B-2014P-US
G6B-2014C-US
G6B-1114P-US
Maximum Switching Capacity
G6B-2114P-US, G6B-2214P-US, G6B-2014P-US
Maximum Switching Capacity
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
DC resistive load
AC inductive load
(cosφ = 0.4)
DC resistive load
Switching voltage (V)
AC inductive load
(cosφ = 0.4)
Switching voltage (V)
Power PCB Relay
Model
AC resistive load
AC resistive
load
G6B
SPST-NO
SPST-NO + SPST-NC
DPST-NO
DPST-NC
Electrical Service Life
Electrical Service Life
Contact form
250 VAC inductive load (cosφ = 0.4)
30 VDC inductive load (L/R = 7 ms)
G6B-1114P(C)-US
250 VAC/30 VDC
inductive load
(cosφ = 0.4, L/R = 7 ms)
Switching current (A)
G6B-1114P(C)-US
250 VAC/30 VDC resistive load
250 VAC resistive load
30 VDC resistive load
Switching current (A)
G6B-1174P(C)-US
250 VAC/30 VDC
resistive load
3 to 24 VDC
Coil rating
Note: The maximum coil voltage refers
Ambient Temperature vs.
Maximum Coil Voltage
to the maxi-mum value in a
varying range of operating power
voltage, not a continuous voltage.
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
5 A at 250 VAC (General Use) 80°C
5 A at 30 VDC (Resistive) 80°C
8 A at 250 VAC (General Use) 80°C
8 A at 30 VDC (Resistive) 80°C
5 A at 250 VAC (general use) 40°C
5 A at 30 VDC (resistive load) 40°C
Ambient temperature (°C)
G6B-1174P-US
G6B-1114P-US
Contact rating