RF313-12 TELEDYNE, RF313-12 Datasheet

RF (Radio Frequency) Relays 12V DC-6GHz .15W hi sensitivity

RF313-12

Manufacturer Part Number
RF313-12
Description
RF (Radio Frequency) Relays 12V DC-6GHz .15W hi sensitivity
Manufacturer
TELEDYNE
Series
RF313r
Datasheet

Specifications of RF313-12

Coil Resistance
850 Ohms
Frequency
3 GHz
Contact Form
SPST - NC / DPST - NO
Coil Voltage
12 VDC
Power Consumption
200 mW
Termination Style
PCB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
©2003 TELEDYNE RELAYS
Temperature
(Ambient)
Vibration
(General Note 1)
Shock
(General Note 1)
Enclosure
Weight
STATIONARY
CONTACT
INTERNAL CONSTRUCTION
CONTACT
LOWER
MOVING
STATIONARY
CONTACT
BYPASS
UPPER
PHYSICAL SPECIFICATIONS
ENVIRONMENTAL AND
Storage
Operating –55°C to +85°C
RF310
RF313
DESIGNATION
SERIES
RF310
RF313
–65°C to +125°C
10 g’s to 500 Hz
30 g’s,
6 msec, half-sine
Hermetically sealed
0.09 oz. (2.55g) max.
0.16 oz. (4.5g) max.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
ARMATURE
UNI-FRAME
Repeatable, RF, N.C. bypass relay
Sensitive, repeatable, RF, N.C. bypass relay
HIGH REPEATABILITY,
NORMALLY CLOSED,
BYPASS RF RELAYS
PERFORMANCE FEATURES
The ultraminiature RF310 and RF313 relays are designed with an internal
bypass (through path), when the coil is de-energized, to provide low insertion
loss and VSWR through the bypass and simplicity of design for the user.
Relays have improved RF insertion loss repeatability over the frequency range
from dc to 3 GHz. Highly suitable for use in attenuator, linear amplifier and
other RF circuits. The RF310 and RF313 feature:
• N.C. bypass configuration.
• Repeatable insertion loss.
• Broad bandwidth.
• Metal enclosure for EMI shielding.
• Ground pin option to improve case RF grounding.
• High isolation between control and signal paths.
• High resistance to ESD.
CONSTRUCTION FEATURES
The following unique construction features and manufacturing techniques
provide excellent resistance to environmental extremes and overall high
reliability.
• Uni-frame motor design provides high magnetic efficiency and mechanical
• Minimum mass components and welded construction provide maximum
• Advanced cleaning techniques provide maximum assurance of internal
• Gold-plated precious metal alloy contacts ensure reliable switching.
rigidity.
resistance to shock and vibration.
cleanliness.
www.teledynerelays.com
RELAY TYPE
RF310 RF313 Page 1
SERIES
RF310
RF313
RF310 RF313/1203/Q1

Related parts for RF313-12

RF313-12 Summary of contents

Page 1

... Repeatable, RF, N.C. bypass relay Sensitive, repeatable, RF, N.C. bypass relay PERFORMANCE FEATURES The ultraminiature RF310 and RF313 relays are designed with an internal bypass (through path), when the coil is de-energized, to provide low insertion loss and VSWR through the bypass and simplicity of design for the user. ...

Page 2

... VSWR -0.8 -0.9 -1.0 .3MHz 1.0 2.0 Frequency (GHz) INSERTION LOSS AND VSWR CHARACTERISTICS RF313 RELAYS Typical Characteristics for N.O. Contacts, Per Pole, Coil Energized (Note 4) 0.0 INSERTION LOSS -0.1 -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0 ...

Page 3

... SMA connectors. (RT/duroid www.teledynerelays.com Typical Repeatability Data, Bypass 0.06 0.08 0.1 0.12 0.14 0.16 0.18 Repeatability (dB) 0.06 0.08 0.1 0.12 0.14 0.16 0.18 Repeatability (dB) ® RF310 RF313 Page 3 RF310 RF313/1203/Q1 0.2 0.2 ...

Page 4

... DIA. EXTERNAL DIMENSIONS www.teledynerelays.com N.O. side (coil energized) DPST, Normally Open Continuous 4.0 ms. max. 6.0 ms. max. 3.0 ms. max. 3.0 ms. max. 0.4 pF typical RF310-12 RF313-12 12.0 390 850 9.0 .370 (9.40) DIA. MAX. .335 (8.51) DIA. MAX. H DIMENSION H MAX. ...

Page 5

... RF300, RF310, RF320 H Dim ER420, ER422D, ER420DD, 421, MAX ER421D, ER421DD, ER422, ER422D, ER422DD, 722, 722D, RF341 ER431T, ER432T, ER432, ER432D, ER432DD 732, 732D, 732TN, RF303, RF313, RF323 RF312 ER411, ER411D, ER411DD H Dim MAX ER431, ER431D, ER431DD RF311 RF331 ...

Page 6

... Dim H MAX .014 [0.36] (REF) .370 [9.4] MIN +44 (0) 1236 453124 • www.teledyne-europe.com For use with the following: ER411T, J411T, ER412, ER412D ER412DD, J412, J412D, J412DD ER412T, J412T 712, 712D, 712TN ER431T, J431T, ER432, ER432D ER432DD, J432, J432D, J432DD ER432T, J432T ...

Page 7

... Appendix A: Ground Pin Positions Ø.200 [Ø5.08] 36° ±3° TO-5 Relays: ER411T, ER412, ER412T, ER420, ER421, ER422, ER431T, ER432, ER432T, 712, 712TN, 400H, 400K, 400V, RF300, RF303, RF341, RF312, RF310, RF313, RF320, RF323 .100 [2.54] .100 [2.54] .050 [1.27] .100 [2.54] Centigrid® ...