RF103-5 TELEDYNE, RF103-5 Datasheet
RF103-5
Specifications of RF103-5
Related parts for RF103-5
RF103-5 Summary of contents
Page 1
... PERFORMANCE FEATURES The ultraminiature RF100 and RF103 relays are designed to provide improved RF signal repeatability over the frequency range. These relays are highly suitable for use in attenuator and other RF circuits, the RF100 and RF103 feature: • High repeatability. • Broader bandwidth. ...
Page 2
... SERIES RF100 AND RF103 TYPICAL RF CHARACTERISTICS (See RF Notes) Isolation Across Contacts (RF Note 4) -20 -30 -40 -50 -60 0 500 1000 1500 2000 2500 3000 3500 Frequency (MHz) Insertion Loss (RF Note 6) 0 -0.2 -0.4 -0.6 -0.8 -1 -1.2 -1.4 -1.6 -1.8 0 500 1000 1500 2000 2500 ...
Page 3
... Test performed at room ambient temperature. d. Contact signal level: 20 dBm. 2. Data presented herein represents typical characteristics and is not intended for use as specification limits. 3. Insertion loss repeatability measured over frequency range from .3 MHz to 4 GHz. RF100 RF103 Page 3 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Normally Open 100 ...
Page 4
... RF100: 369–500 mW typical @ nominal rated voltage RF103: 180–250 mW typical @ nominal rated voltage RF100 RF103 RF100 RF103 1,000 MΩ min. (between mutually isolated terminals) 350 VRMS / atmospheric pressure RF100-5 RF103-5 5.0 RF100 50 RF103 100 3.6 .031 (.79) REF. .035 (.89) ...
Page 5
... ER431, ER431D, ER431DD RF311 RF331 172, 172D ER114, ER114D, ER114DD, Dim H J114, J114D, J114DD MAX ER134, ER134D, ER134DD, J134, J134D, J134DD RF100 RF103 122C, A152 ER116C, J116C H Dim MAX ER136C, J136C RF180 A150 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Dim. H Max. .295 (7.49) ...
Page 6
... Dim H MAX .014 [0.36] (REF) .370 [9.4] MIN +44 (0) 1236 453124 • www.teledyne-europe.com For use with the following: ER411T, J411T, ER412, ER412D ER412DD, J412, J412D, J412DD ER412T, J412T 712, 712D, 712TN ER431T, J431T, ER432, ER432D ER432DD, J432, J432D, J432DD ER432T, J432T ...
Page 7
... POSITION "U" POSITION (ER116C and ER136C only) Centigrid® Relays: RF100, RF103, ER114, ER134, 172 NOTES 1. Terminal views shown 2. Dimensions are in inches (mm) 3. Tolerances: ± .010 (±.25) unless otherwise speci¿ Ground pin positions are within .015 (0.38) dia. of true position 5 ...