AWM3100V Honeywell, AWM3100V Datasheet

no-image

AWM3100V

Manufacturer Part Number
AWM3100V
Description
Flow Sensors + 200 sccm Straight
Manufacturer
Honeywell
Datasheets

Specifications of AWM3100V

Sensor Type
Air Flow
Rated Range
200 cm/min
Accuracy/reliability
+/- 0.5 % Reading
Analog Output
5 V
Supply Voltage
10 V
Brand/series
AWM3000
Function
AirFlow
Output
Voltage
Primary Type
AirFlow
Range, Measurement
200 sccm
Technology
Thermal Conductive
Termination
3-Wire Connector
Voltage, Supply
15 VDC
Voltage, Switching
5 VDC
Operating Temperature
–13° to +185°F
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AWM3100V
Manufacturer:
HONEYWELL
Quantity:
2 000
AWM3100V
Actual product appearance may vary.
Description
Like the AWM2000 Series, the dual Wheatstone bridges control airflow
measurement. The AWM3000 Series is amplified; therefore, it can be used to
increase the gain and to introduce voltage offsets to the sensor output. The heater
control circuit and the sensing bridge supply circuit are on board the package.
Features
interchangeability
CAUTION
PRODUCT DAMAGE
AWM Series Microbridge Mass Airflow Sensors are not designed to sense
liquid flow and will be damaged by liquid flow through the sensor.
Failure to comply with these instructions could result in product
damage.
Laser trimmed for improved sensor
Flow sensing up to 1.0 SLPM
Low differential pressure sensing
Airflow Sensor, Signal Conditioning:
Amplified; Flow/Pressure Range: + 200
sccm; Port Style: Straight
Potential Applications
ventilation, and air conditioning
systems
Damper control for heating,
Gas analyzers
Low vacuum control
Process control
Medical respirators and ventilators
Oxygen concentrators
Leak detection equipment
Vent hoods
Anesthesia control
Gas metering
Gas chromatography

Related parts for AWM3100V

AWM3100V Summary of contents

Page 1

... AWM3100V Airflow Sensor, Signal Conditioning: Amplified; Flow/Pressure Range: + 200 sccm; Port Style: Straight Actual product appearance may vary. Features Laser trimmed for improved sensor interchangeability Flow sensing up to 1.0 SLPM Low differential pressure sensing Description Like the AWM2000 Series, the dual Wheatstone bridges control airflow measurement. The AWM3000 Series is amplified ...

Page 2

... Signal Conditioning Flow/Pressure Range Output Voltage @ Trim Point Port Style Series Name Null Shift over Temperature Output Shift over Temperature Maximum change in flow rate Max. Repeatability & Hysteresis Error Null Offset Response Time Supply Voltage Maximum Common Mode Pressure Power Consumption ...