0.5 INCH-G-4V All Sensors Corporation, 0.5 INCH-G-4V Datasheet - Page 2

no-image

0.5 INCH-G-4V

Manufacturer Part Number
0.5 INCH-G-4V
Description
Industrial Pressure Sensors 0.5" Gauge 4.5-5.5VDC supply
Manufacturer
All Sensors Corporation
Datasheet

Specifications of 0.5 INCH-G-4V

Operating Pressure
0.5 in H2O
Pressure Type
Gauge
Accuracy
+/- 0.05 %
Output Type
Amplified
Mounting Style
Through Hole
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 25 C
Operating Supply Voltage
4.5 V to 5.5 V
Package / Case
SIP-4
Output Voltage
4 V
Port Size
4.4 mm to 4.8 mm
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Pressure Sensor Characteristics Maximum Ratings
Performance Characteristics for 4 INCH-D-4V
Performance Characteristics for 4 INCH-G-4V
Supply Supply Voltage VS
Common-mode pressure
Lead Temperature
(soldering 2-4 sec.)
Specification Notes
NOTE
NOTE
NOTE
NOTE
NOTE
Parameter, note 1
Operating Range, differential pressure
Output Span, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (5°C-50°C), note 2
Linearity, hysteresis error, note 4
Full Scale Shift (5°C-50°C), note 2
Parameter, note 1
Operating Range, gage pressure
Output Span, note 5
Offset Voltage @ zero pressure
Offset Temperature Shift (5°C-50°C), note 2
Linearity, hysteresis error, note 4
Full Scale Shift (5°C-50°C), note 2
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any
product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
UNLESS OTHERWISE SPECIFIED
4.25
1: A
2: S
3: S
4: M
5: T
VOLTS FOR MINUS TO PLUS FULL SCALE PRESSURE
HIFT IS RELATIVE TO
HIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE
HE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE
LL PARAMETERS ARE MEASURED AT
EASURED AT ONE
-
HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT
25°C.
. P
RESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO
5.0
VOLT EXCITATION
.
Equivalent Circuit
,
FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE
+3 to +7 Vdc
10 psig
. N
.
250°C
Minimum
Minimum
4-31
OMINALLY THE OUTPUT VOLTAGE RANGE IS
±1.90
2.15
3.90
0.15
Environmental Specifications
Temperature Ranges
Compensated
Operating
Storage
Humidity Limits
.
P
Nominal
Nominal
ORT
0.05
0.05
B.
±4.0
±2.0
2.25
0.25
4.0
4.0
0.25
Maximum
Maximum
TO
±2.10
2.35
0.25
4.10
0.35
0.25
±40
±40
±2
±2
(non condensing)
-40 to 125° C
%span
%span
0 to 95% RH
“ H2O
“ H2O
-25 to 85° C
mvolt
mvolt
Units
Units
volt
volt
%fs
volt
volt
%fs
5 to 50° C
4

Related parts for 0.5 INCH-G-4V