OD1232-SPOT Orion Fans, OD1232-SPOT Datasheet

Fans & Blowers 120VAC / 60Hz Input 19W, 47dBA

OD1232-SPOT

Manufacturer Part Number
OD1232-SPOT
Description
Fans & Blowers 120VAC / 60Hz Input 19W, 47dBA
Manufacturer
Orion Fans
Datasheet

Specifications of OD1232-SPOT

Current Type
DC
Airflow
65 CFM to 120 CFM
Speed
1600 RPM
Frame Dimensions (mm)
120 mm x 32 mm
Housing Material
Polybutylene Terephthalate
Termination Style
Wire Leads
Product
Fans
Bearing Type
Dual Ball
Noise
47 dBA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rating information is +/-10%
Data and specifications are subject to change without prior notification
Part No. (ENG SKU)
Fan ID
VOLTAGE INPUT
INPUT POWER
DC Nominal Current
DC Locked Current
Rated Speed (RPM)
Airflow (CFM)/Temp
Noise Level (dB)
Max. Static Pressure
Bearing System
Frame & Impeller
Connection
Motor
Bearing System
Insulation Resistance
Dielectric Strength
Operation
Temperature
Life (L10)
OD1232-SPOT
OD1232-12HB-03
120VAC / 60Hz
19 Watts
0.60 A
0.05 A
1600 Max. (40C)
65 ~ 120 / 25C~40C
47
0.43” H 2 O
Dual Ball
PBT, UL94V-O plastic
[ see installation instructions, item 4. ]
Brushless DC, auto restart, polarity pro-
tected. Thermal Control.
Dual ball bearing
10M ohm between leadwire and frame
(500VDC)
5mA max at 1500VAC for 1 minute
between the leadwire and frame
-10C ~ +70C
60,000 hours
General Notes:
A. Always ensure power is disconnected before working on or
installing this component
B. Maker assumes no responsibility for suitability of purpose in
any installation
C. Do not wear loose clothing or accessories that may become
entangled in moving parts while
assembling or operating this component.
Installation Instructions:
Tools and parts required (Not supplied with this unit):
(4x) 8-32 x 1⁄2” screws
(4x) 8-32 nut
( 1 ) G109-15A (or equivalent) 120mm finger guard
1. Cut an opening in the enclosure wall as shown in the
diagram [below]
2. Place fan [right] so that the 8-32x 1⁄2” screws pass through
the outer grill and the fan flange.
3. Place the 8-32 nut in place as shown and tighten
4. Plug 12V adaptor provided into the receptacle on the fan and
into an appropriate 120V power
source.
The fan will operate at low to medium speed and will increase
speed as more cooling is necessary in the
application.
panel cutout
Description
Thermistor
Airflow Range:
65CFM at 25C or
below ramping up to
120CFM at 40C+
Contact:
214-340-0265 (Tel)
214-340-5870 (Fax)
frame dimensions only:
adapter, cord, connector
and receptacle not shown
NOTES:
Unit Includes:
6 foot cord with
fan connector

Related parts for OD1232-SPOT

Related keywords