B1240 Protek, B1240 Datasheet

Function Generators & Synthesizers SYNTHESIZED 1040 MHZ AM/FM SIG GENERATOR

B1240

Manufacturer Part Number
B1240
Description
Function Generators & Synthesizers SYNTHESIZED 1040 MHZ AM/FM SIG GENERATOR
Manufacturer
Protek
Datasheet

Specifications of B1240

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B1240
Manufacturer:
RONM
Quantity:
20 000
Part Number:
B1240-Q
Manufacturer:
ROHM
Quantity:
68 000
Part Number:
B1240-Q
Manufacturer:
ROHM
Quantity:
5 000
Part Number:
B1240-R
Manufacturer:
ROHM
Quantity:
68 000
Part Number:
B1240-R
Manufacturer:
ROHM
Quantity:
5 000
40
Protek Test & Measurement
45 Smith Street, Englewood, NJ 07631 Tel: 201-818-7711 Fax: 201-760-9888
Website: www.protektest.com Email: sales@protektest.com
B1240
S P E C I F I C A T I O N S
Frequency:
Range:
Display Resolution:
10Hz (10KHz to 520MHz), 20Hz (520MHz to 1040MHz)
Accuracy:
Output Characteristics:
Output level Range:
Display Resolution:
Accuracy:
Amplitude Flatness:
< 0.5dB (10KHz to 1040KHz, -10dBm to +6dBm)
Output impedance:
Amplitude Units:
Output Protection:
Spectral Purity:
Spurious:
Better than -35dB at carrier frequency < 62.5MHz and 0dBm
Better than -25dB at carrier frequency > 62.5MHz and 0dBm
Residual Modulation:
Modulation
FM:
Deviation:
0 to 100KHz (1Mz to 1040MHz)
Carrier Freq. x 10% (below 1MHz)
Resolution:
10Hz (0 to 10KHz deviation)
100Hz (10KHz to 100KHz deviation)
10KHz to 1040MHz
±1.5 x 10
±1dB (> -10dBm), ±2dB (< -10dBm)
dBm and dBµ
25W of reverse power
-6
50Ω
0.1dB
-127dBm to + 6dBm
after 20 minutes of warm up
FM: 7Hz, AM: 0.05%
Synthesized AM/FM
Signal Generator
10 KHz to 1040KHz frequency range
AM, PM and FM modulation
-127dBm to +6dBm output level
Self Test and Calibration capabilities
25W reverse power protection
100 location memory for storing Frequency, modulation and output level data
Optional GPIB interface
Accuracy:
Frequency Response:
Distortion:
Carrier Freq. > 250KHz)
PM:
Range:
Resolution:
Frequency Response:
Deviation Accuracy:
AM:
Range:
Resolution:
Accuracy:
Frequency Response:
Envelope Distortion:
Modulation Oscillator:
External modulation Input:
Input Impedance:
Memory:
Locations 0 to 19 store Frequency, Modulation and Output level
data; Locations 20 to 99 store Frequency data only;
3 independent memories for storing output level data.
Range: 10Hz to 50KHz
Input Level: 0.9V to 1.1V RMS (With Modulation ALC)
0 to 10 Radians
0 to 99%
±5% for 1KHz or 400Hz modulation
better than ±4% of depth setting + 1% at 1KHz
< 2% THD (1KHz Mod., Max deviation and
0.01 Radians
0.5%
100KΩ (Approx.)
±5% at 1KHz Modulation
< 3% THD (at 70% mod and 1KHz)
±0.5dB (50Hz to 50KHz)
±1dB (10KHz to 10KHz)
±0.5% (50Hz to 50KHz)
Frequency: 1KHz and 400Hz
B1240
Display:
Carrier Frequency:
Modulation:
Output Level:
Memory Location:
General Specifications
Input Power:
Frequency:
Size:
Weight:
Standard Accessories:
Operation manual, Line cord and Type N cable
Optional Accessories:
GBIB interface
4.7" (H) x 17" (W) x 17.7" (D)
26.5 lbs
50/60
3-digit LED
110/220V
4 -digit LED
2-digit LED
9-digit LED

B1240 Summary of contents

Page 1

... Protek Test & Measurement 45 Smith Street, Englewood, NJ 07631 Tel: 201-818-7711 Fax: 201-760-9888 40 Website: www.protektest.com Email: sales@protektest.com B1240 Accuracy: ±5% for 1KHz or 400Hz modulation Frequency Response: ±0.5dB (50Hz to 50KHz) Distortion: < 2% THD (1KHz Mod., Max deviation and Carrier Freq. > ...

Page 2

... Function Key, Some keys on the front are dual function, pressing this key enables the second function. STD FREQ REMOCON INPUT DC 5V STD FREQ ADJ 45 Smith Street, Englewood, NJ 07631 Tel: 201-818-7711 Fax: 201-760-9888 B1240 19. Selects if data is being stored in or recalled from the displayed memory ...