LTC2942IDCB-1#PBF Linear Technology, LTC2942IDCB-1#PBF Datasheet - Page 9

IC, BATTERY FUEL GAUGE LI-ION 5.5V DFN-6

LTC2942IDCB-1#PBF

Manufacturer Part Number
LTC2942IDCB-1#PBF
Description
IC, BATTERY FUEL GAUGE LI-ION 5.5V DFN-6
Manufacturer
Linear Technology
Datasheet

Specifications of LTC2942IDCB-1#PBF

Battery Management Function
Fuel Gauge, Charge Controller
Battery Type
Li-Ion
Supply Voltage Range
2.7V To 5.5V
Battery Ic Case Style
DFN
No. Of Pins
6
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LTC2942IDCB-1#PBFLTC2942IDCB-1
Manufacturer:
LT
Quantity:
10 000
Company:
Part Number:
LTC2942IDCB-1#PBF
Manufacturer:
LT
Quantity:
17
Company:
Part Number:
LTC2942IDCB-1#PBFLTC2942IDCB-1#TRMPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC2942IDCB-1#PBFLTC2942IDCB-1#TRPBF
Manufacturer:
LT
Quantity:
5 600
applicaTions inFormaTion
Status Register (A)
The status of the charge, voltage and temperature alerts
is reported in the status register shown in Table 2.
Table 2. Status Register A (Read only)
All status register bits except A[7] are cleared after being
read by the host, if the conditions which set these bits
have been removed.
As soon as one of the three measured quantities exceeds
the programmed limits, the corresponding bit A[4], A[3],
A[2] or A[1] in the status register is set.
Bit A[5] is set if the LTC2942’s accumulated charge registers
(ACR) overflows or underflows. In these cases, the ACR
stays at FFFFh or 0000h and does not roll over.
The undervoltage lockout (UVLO) bit of the status register
A[0] is set if, during operation, the voltage on SENSE
pin drops below 2.7V without reaching the POR level.
The analog parts of the coulomb counter are switched off
while the digital register values are retained. After recov-
ery of the supply voltage the coulomb counter resumes
integrating with the stored value in the accumulated
charge registers but it has missed any charge flowing
while SENSE
A[7] Chip Identification
A[6] Reserved
A[5] Accumulated Charge
A[4] Temperature Alert
A[3] Charge Alert High
A[2] Charge Alert Low
A[1] Voltage Alert
A[0] Undervoltage
BIT
NAME
Overflow/Underflow
Lockout Alert
+
< 2.7V.
OPERATION
0: LTC2942
1: LTC2941
Indicates that the value of the
ACR hit either top or bottom.
Indicates one of the
temperature limits was
exceeded.
Indicates that the ACR value
exceeded the charge threshold
high limit.
Indicates that the ACR value
dropped below the charge
threshold low limit.
Indicates one of the battery
voltage limits was exceeded.
Indicates recovery from
undervoltage. If set to 1, a
UVLO has occurred and the
contents of the registers are
uncertain.
DEFAULT
X
0
0
0
0
0
0
0
+
The hard-coded bit A[7] of the status register enables the
host to distinguish the LTC2942 from the pin compatible
LTC2941, allowing the same software to be used with
both devices.
Control Register (B)
The operation of the LTC2942 is controlled by program-
ming the control register. Table 3 shows the organization
of the 8-bit control register B[7:0].
Table 3. Control Register B
Power Down B[0]
Setting B[0] to 1 shuts down the analog parts of the
LTC2942, reducing the current consumption to less than
1µA. All analog circuits are inoperative while the values
in the registers are retained. Note that any charge flowing
while B[0] is 1 is not measured and the charge information
below 1LSB of the accumulated charge register is lost.
B[7:6] ADC Mode
B[5:3] Prescaler M
B[2:1] AL/CC Configure Configures the AL/CC pin.
B[0]
BIT
NAME
Shutdown
OPERATION
[11] Automatic Mode.
Performs voltage and temperature
conversion every second.
[10] Manual Voltage Mode.
Performs single voltage
conversion, then sleeps.
[01] Manual Temperature Mode.
Performs single temperature
conversion, then sleeps.
[00] Sleep.
Sets coulomb counter prescaling
factor M between 1 and 128.
Default is 128.
M = 2
[10] Alert Mode.
Alert functionality enabled.
Pin becomes logic output.
[01] Charge Complete Mode.
Pin becomes logic input and
accepts “charge complete” signal
(e.g., from a charger) to set
accumulated charge register (C, D)
to FFFFh.
[00] AL/CC pin disabled.
[11] Not allowed.
Shut down analog section to
reduce I
(4 • B[5] + 2 • B[4] + B[3])
SUPPLY
.
LTC2942
Default
[111]
[00]
[10]
[0]
2942fa


Related parts for LTC2942IDCB-1#PBF