S29AL032D70TFI030 Spansion Inc., S29AL032D70TFI030 Datasheet - Page 34

IC, FLASH, 32MBIT, 70NS, TSOP-48

S29AL032D70TFI030

Manufacturer Part Number
S29AL032D70TFI030
Description
IC, FLASH, 32MBIT, 70NS, TSOP-48
Manufacturer
Spansion Inc.
Datasheet

Specifications of S29AL032D70TFI030

Memory Type
Flash
Memory Size
32Mbit
Memory Configuration
4M X 8 / 2M X 16
Ic Interface Type
CFI, Parallel
Access Time
70ns
Supply Voltage Range
2.7V To 3.6V
Memory Case Style
TSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S29AL032D70TFI030
Manufacturer:
SPANSION
Quantity:
2 526
Part Number:
S29AL032D70TFI030
Manufacturer:
TOSHIBA
Quantity:
2 437
Part Number:
S29AL032D70TFI030
Manufacturer:
SPANSION
Quantity:
7 029
Part Number:
S29AL032D70TFI030
Manufacturer:
SPANSION
Quantity:
20 000
11. Command Definitions
11.1
11.2
11.3
32
Reading Array Data
Reset Command
Autoselect Command Sequence
Writing specific address and data commands or sequences into the command register initiates device
operations.
and data values or writing them in the improper sequence resets the device to reading array data.
All addresses are latched on the falling edge of WE# or CE#, whichever happens later. All data is latched on
the rising edge of WE# or CE#, whichever happens first. Refer to the appropriate timing diagrams under
Characteristics.
The device is automatically set to reading array data after device power-up. No commands are required to
retrieve data. The device is also ready to read array data after completing an Embedded Program or
Embedded Erase algorithm.
After the device accepts an Erase Suspend command, the device enters the Erase Suspend mode. The
system can read array data using the standard read timings, except that if it reads at an address within erase-
suspended sectors, the device outputs status data. After completing a programming operation in the Erase
Suspend mode, the system may once again read array data with the same exception. See
Erase Resume Commands on page 35
The system must issue the reset command in order to re-enable the device for reading array data if DQ5 goes
high, or while in the autoselect mode. See
See also
page 49
Writing the reset command to the device resets the device to reading array data. Address bits are don’t care
for this command.
The reset command may be written between the sequence cycles in an erase command sequence before
erasing begins. This resets the device to reading array data. Once erasure begins, however, the device
ignores reset commands until the operation is complete.
The reset command may be written between the sequence cycles in a program command sequence before
programming begins. This resets the device to reading array data (also applies to programming in Erase
Suspend mode). Once programming begins, however, the device ignores reset commands until the operation
is complete.
The reset command may be written between the sequence cycles in an autoselect command sequence.
Once in the autoselect mode, the reset command must be written to return to reading array data (also applies
to autoselect during Erase Suspend).
If DQ5 goes high during a program or erase operation, writing the reset command returns the device to
reading array data (also applies during Erase Suspend).
The autoselect command sequence allows the host system to access the manufacturer and devices codes,
and determine whether a sector is protected.
requirements. This method is an alternative to that shown in
programmers and requires V
The autoselect command sequence is initiated by writing two unlock cycles, followed by the autoselect
command. The device then enters the autoselect mode, and the system may read at any address any
number of times, without initiating another command sequence.
A read cycle at address 0XXX00h retrieves the manufacturer code. A read cycle at address 0XXX01h returns
the device code. A read cycle containing a sector address (SA) and the address 02h in word mode (or 04h in
byte mode) returns 01h if that sector is protected, or 00h if it is unprotected. Refer to
and
The system must write the reset command to exit the autoselect mode and return to reading array data.
Table 7.5 on page 17
provides the read parameters, and
Requirements for Reading Array Data on page 13
Table 11.2 on page 38
for valid sector addresses.
ID
on address bit A9.
defines the valid register command sequences. Writing incorrect address
S29AL032D
for more information on this mode.
Reset Command on page
Figure 17.1 on page 49
D a t a
Table 11.2 on page 38
S h e e t
for more information. The
Table on page
shows the timing diagram.
shows the address and data
32.
21, which is intended for PROM
S29AL032D_00_A9 January 19, 2007
Table 7.3 on page 15
Read Operations on
Erase Suspend/
AC