SST39VF1601-70-4I-EKE SILICON STORAGE TECHNOLOGY, SST39VF1601-70-4I-EKE Datasheet - Page 5

no-image

SST39VF1601-70-4I-EKE

Manufacturer Part Number
SST39VF1601-70-4I-EKE
Description
MEMORY, FLASH, 16MBIT, B/B, 48TSOP
Manufacturer
SILICON STORAGE TECHNOLOGY
Datasheet

Specifications of SST39VF1601-70-4I-EKE

Memory Size
16Mbit
Supply Voltage Range
2.7V To 3.6V
Memory Case Style
TSOP
No. Of Pins
48
Operating Temperature Range
-40°C To +85��C
Svhc
No SVHC (18-Jun-2010)
Access Time
70ns
Memory Type
Flash - NOR
Memory Configuration
1M X 16
Interface Type
CFI
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SST39VF1601-70-4I-EKE
Manufacturer:
SST44
Quantity:
51
Part Number:
SST39VF1601-70-4I-EKE
Manufacturer:
ST
0
Part Number:
SST39VF1601-70-4I-EKE
Manufacturer:
SST
Quantity:
20 000
16 Mbit / 32 Mbit Multi-Purpose Flash Plus
SST39VF1601 / SST39VF3201
SST39VF1602 / SST39VF3202
Product Identification
The Product Identification mode identifies the devices as
the SST39VF1601, SST39VF1602, SST39VF3201, or
SST39VF3202, and manufacturer as SST. This mode
may be accessed software operations. Users may use
the Software Product Identification operation to identify
the part (i.e., using the device ID) when using multiple
manufacturers in the same socket. For details, see Table
6 for software operation, Figure 12 for the Software ID
Entry and Read timing diagram and Figure 22 for the
Software ID Entry command sequence flowchart.
TABLE 3: Product Identification
Product Identification Mode Exit/
CFI Mode Exit
In order to return to the standard Read mode, the Software
Product Identification mode must be exited. Exit is accom-
plished by issuing the Software ID Exit command
sequence, which returns the device to the Read mode.
This command may also be used to reset the device to the
Read mode after any inadvertent transient condition that
apparently causes the device to behave abnormally, e.g.,
not read correctly. Please note that the Software ID Exit/
CFI Exit command is ignored during an internal Program or
Erase operation. See Table 6 for software command
codes, Figure 14 for timing waveform, and Figures 22 and
23 for flowcharts.
©2008 Silicon Storage Technology, Inc.
Manufacturer’s ID
Device ID
SST39VF1601
SST39VF1602
SST39VF3201
SST39VF3202
Address
0000H
0001H
0001H
0001H
0001H
234BH
234AH
235BH
235AH
Data
BFH
T3.2 1223
5
Security ID
The SST39VF160x/320x devices offer a 256-bit Security
ID space. The Secure ID space is divided into two 128-bit
segments - one factory programmed segment and one
user programmed segment. The first segment is pro-
grammed and locked at SST with a random 128-bit num-
ber. The user segment is left un-programmed for the
customer to program as desired.
To program the user segment of the Security ID, the user
must use the Security ID Word-Program command. To
detect end-of-write for the SEC ID, read the toggle bits. Do
not use Data# Polling. Once this is complete, the Sec ID
should be locked using the User Sec ID Program Lock-Out.
This disables any future corruption of this space. Note that
regardless of whether or not the Sec ID is locked, neither
Sec ID segment can be erased.
The Secure ID space can be queried by executing a three-
byte command sequence with Enter Sec ID command
(88H) at address 5555H in the last byte sequence. To exit
this mode, the Exit Sec ID command should be executed.
Refer to Table 6 for more details.
S71223-05-000
Data Sheet
6/08

Related parts for SST39VF1601-70-4I-EKE