LM96000CIMT National Semiconductor, LM96000CIMT Datasheet - Page 9

no-image

LM96000CIMT

Manufacturer Part Number
LM96000CIMT
Description
IC,Data Acquisition System,7-CHANNEL,8-BIT,TSSOP,24PIN,PLASTIC
Manufacturer
National Semiconductor
Datasheets

Specifications of LM96000CIMT

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LM96000CIMT
Quantity:
149
Part Number:
LM96000CIMT/NOPB
Manufacturer:
EPCOS
Quantity:
3 186
Part Number:
LM96000CIMTX
Manufacturer:
PERICOM
Quantity:
45
Part Number:
LM96000CIMTX
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM96000CIMTX/NOPB
Manufacturer:
MAXIM
Quantity:
4
Part Number:
LM96000CIMTX/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
Register
Address
20h
21h
22h
23h
24h
25h
26h
27h
28h
29h
2Ah
2Bh
2Ch
2Dh
2Eh
2Fh
30h
31h
32h
3Eh
3Fh
40h
41h
42h
43h
44h
45h
46h
47h
48h
Functional Description
1. Set limits and parameters (not necessarily in this order):
2. [40h] Set bit 0 (START) to update fan control and limit register values and start fan control based on these new values.
3. [40h] Set bit 1 (LOCK) to lock the fan limit and parameter registers (optional).
3.0 AUTO FAN CONTROL OPERATING MODE
The LM96000 includes the circuitry for automatic fan control. In Auto Fan Mode, the LM96000 will automatically adjust the PWM
duty cycle of the PWM outputs. PWM outputs are assigned to a thermal zone based on the fan configuration registers. It is
possible to have more than one PWM output assigned to a thermal zone. For example, PWM outputs 2 and 3, connected to two
chassis fans, may both be controlled by thermal zone 2. At any time, the temperature of a zone exceeds its absolute limit, all PWM
outputs will go to 100% duty cycle to provide maximum cooling to the system.
4.0 REGISTER SET
– [5F-61h] Set PWM frequencies and auto fan control range.
– [62-63h] Set spike smoothing and min/off.
– [5C-5Eh] Set the fan spin-up delays.
– [5C-5Eh] Match each fan with a corresponding thermal zone.
– [67-69h] Set the fan temperature limits.
– [6A-6Ch] Set the temperature absolute limits.
– [64-66h] Set the PWM minimum duty cycle.
– [6D-6Eh] Set the temperature Hysteresis values.
Read/
Write
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/W
R/W
R/W
R
R
R/W
R
R
R
R/W
R/W
R/W
R/W
R/W
Register
Name
2.5V
VCCP_IN
3.3V
5V
12V
Processor (Zone1) Temp
Internal (Zone2) Temp
Remote (Zone3) Temp
Tach1 LSB
Tach1 MSB
Tach2 LSB
Tach2 MSB
Tach3 LSB
Tach3 MSB
Tach4 LSB
Tach4 MSB
Fan1 Current PWM Duty
Fan2 Current PWM Duty
Fan3 Current PWM Duty
Company ID
Version/Stepping
Ready/Lock/Start/Override
Interrupt Status Register 1
Interrupt Status Register 2 ERR2 ERR1 FAN4 FAN3
VID0–4
2.5V Low Limit
2.5V High Limit
VCCP Low Limit
VCCP High Limit
3.3V Low Limit
(Continued)
(MSB)
VER3 VER2 VER1 VER0
Bit 7
RES
ERR
RES
15
15
15
15
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
Bit 6
RES
RES
ZN3
14
14
14
14
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Bit 5
RES
RES
ZN2
13
13
13
13
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
9
Bit 4
VID4
RES OVRID READY
ZN1
12
12
12
12
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
STP3
FAN2
Bit 3
VID3
5V
11
11
11
11
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
STP2
FAN1
Bit 2
VID2
3.3V
10
10
10
10
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
LEVEL1 LEVEL0
LEVEL1 LEVEL0
LEVEL1 LEVEL0
LEVEL1 LEVEL0
LOCK
VCCP
STP1
Bit 1
VID1
RES
1
1
1
1
1
1
1
1
9
9
9
9
1
1
1
1
1
1
1
1
1
START
(LSB)
STP0
Bit 0
VID0
2.5V
12V
0
0
0
0
0
0
0
0
8
8
8
8
0
0
0
0
0
0
0
0
0
Default
Value
FFh
FFh
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
01h
68h
00h
00h
00h
N/A
00h
00h
00h
www.national.com
Lock?