MY4 6VDC (S) Omron, MY4 6VDC (S) Datasheet - Page 5

RELAY, 4PCO, 6VDC

MY4 6VDC (S)

Manufacturer Part Number
MY4 6VDC (S)
Description
RELAY, 4PCO, 6VDC
Manufacturer
Omron
Datasheet

Specifications of MY4 6VDC (S)

Relay Type
General Purpose
Coil Voltage Vac Nom
240V
Coil Voltage Vdc Nom
6V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
39.8ohm
Coil Type
DC Coil
Coil
RoHS Compliant
Contact Configuration
4PCO
Rohs Compliant
Yes
MY
Life Expectancy Characteristics
Note: See following tables for real load life expectancies.
MY2
MY2E
MY4
Normal, High-humidity, With test button (except relays
with operation indicator), With CR
High-capacity
With operation indicator or built-in diode
With bifurcated contacts
High-sensitivity
100 VAC
24 VDC
100 VAC
24 VDC
Rated voltage
Rated voltage
Rated voltage
Life Expectancies Under Real Loads
AC motor
AC solenoid
AC lamp
AC solenoid
DC magnetic
switch
AC magnetic
switch
DC solenoid
Load type
Load type
Load type
Relays
50 W, 100 VAC single-phase with
2.8-A inrush current, 0.4-A carry
current
50 W, 100 VAC single-phase with
1.6-A inrush current, 1-A carry current
24 W with 1-A carry current
300 W with 50-A inrush current, 3-A
carry current
50 VA with 2-A inrush current, 0.7A
carry current
25 W with L/R = 40 ms , 0.2-A carry
current
35 VA with 1.5-A inrush current,
0.35-A carry current
40 W with L/R = 10 ms, 1.6-A carry
current
30 W with L/R = 10 ms with 0.34-A
carry current
Conditions
Conditions
Conditions
AC 50,000,000 operations min.
DC: 100,000,000 operations min.
AC 50,000,000 operations min.
DC: 100,000,000 operations min.
AC 50,000,000 operations min.
DC: 100,000,000 operations min.
2-pole: 50,000,000 operations min.
4-pole: 20,000,000 operations min.
100,000,000 operations min.
(at 18,000 operations/hr)
Mechanical life
ON for 2 s, OFF for 30 s
ON for 1 s, OFF for 30 s
ON for 1.5 s, OFF for 1.5 s
ON for 5 s, OFF for 55 s
ON for 1 s, OFF for 3 s
ON for 0.5 s, OFF for 1.5 s
ON for 0.5 s, OFF for 1.5 s
Operating frequency
Operating frequency
Operating frequency
(at 1,800 operations/hr under rated load)
1-,2-,3-pole: 500,000 operations min.
4-pole:
500,000 operations min.
1-,2-,3-pole: 500,000 operations min.
4-pole:
2-pole: 200,000 operations min.
4-pole: 100,000 operations min.
200,000 operations min.
Electrical life
200,000 operations min.
200,000 operations min.
100,000 operations
300,000 operations
4,000,000 operations
55,000 operations
25,000 operations
500,000 operations
5,000,000 operations
6,000,000 operations
Electrical life
Electrical life
Electrical life
MY
5